Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDA E _F <br /> UNDERGROUNDSTORAGETANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION (one fotm per UST) <br /> . 0 1 I I 270WIN&O , , 11 1 r <br /> i <br /> MEM1,01-W­ Not <br /> DATE UST PERMANENTLY CLOSED: M 0 <br /> 43OA- DATE EXISTING UST DISCOVERED: <br /> FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) <br /> _y <br /> Ito <br /> wZVI I <br /> j TANK ID# 431 - 111 Mel I <br /> I TANK MANUFACTURER 433. <br /> 3 OVIENS CORNING <br /> (CAPACITY IN G;�LLONS -36. NUMBER OF COMPARTMENTS IN 437-. <br /> 000 <br /> TANK USE 0 ta.MOTOR <br /> VEHICLE FUELING El Ib MARINUA-FUELING ■ Ic.AVIATION FUELING 4A-7 <br /> 0 3.CHEMICAL PRODUCT STORAGE [3 4.HAZARDOUS WASTE(Immiudes Used(M) 0 5.FMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> (3 6.OTHER GENERATOR FUEL 0 95.UNKNOWN 0 99.OTHER(Specify): 439a. <br /> i_e0__NTENTS PETROLEUM: [3 Is.REGULAR UNLEA 0 Ic.MIDGRADE UNLEADED 1b.PREMIUM UNLEADED 440. <br /> 0 3.DIESEL 0 5.JET FUEL ■ 6.AVIATION GAS <br /> 0 8.PETROLEUM BLEND FUEL El 9.OTHER PETROLEUM(§p�cify): <br /> - 440a. <br /> NON-PETROLEUM:■ 7.USED OIL it 10.ETHANOL <br /> 0 II.OTHERNON1-PETROLEUM(Sm__rjft _ <br /> 440b. <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK Q I-SINGLEWALL M_ 2.DOUBLE WALL 0 95.UNKNOWN 443. <br /> PRIMARY CONTAINMENT 1.STEEL N 3.FIBERGLASS [J 6.INTERNAL BLADDER 444. <br /> E3 7.STEEL+INTERNAL LINING 13 95.UNKNOWN Q 99.OTHER(specio): 444a. <br /> SECONDARY CONTAINMENT [3 L STEEL [9 3*FIBERGLASS C1 6.EXTERIOR MEMBRANE LINER 0 7.JACKETED 445. <br /> 13 90,NONE 13 95.UNKNOWN [3 99.OTHER(Specify): 445a. <br /> OVERFILL PREVENTION 0 1.AUDIBLE&VISUAL ALARMS 0 2.BALL FLOAT- 09 3.FILL TUBE SHUT-OFF VALVE 451 <br /> Q 4.TANK MEETS REQVIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION MUIPMENT - <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION - <br /> PIPING CONSTRUCTION ■ 1.SINGLE WALL 0 2. 1 O6jL_EWAjj [3 99.OTHER <br /> 46D� <br /> SYSTEM TYPE 10 1.PRESSURE <br /> El 2.ORAVI 0 3.CONVENTIONAL SUCTION Ej 4.SAFE SUCTION[23 CCR§1.636(aX3)] 459. <br /> PRIMARY CONTAINMENT 0 1.STEEL C9 4.FIBERGLASS 0 8.FLEXIBLE 0 10.RIGID PLASTIC 464, <br /> 0 90.NONE 0 95.UNKNOWN Ej 99.OTHER(itpeFify): 464L <br /> SECONDARY CONTAINMENT 0 1.STEEL 0 4'.FIBERGLASS C3 8.FLEXIBLE 0 10.RIGID PLASTIC <br /> 464b. <br /> 0 90.NONE C1 95.UNKNOWN 0 99.OTHER(§pEEtk): 464c. <br /> PIPING/TURBFNE CONTAINMENT SUMP TYPE IR I.SINGLE WALL rl 2.DOUBLE WALL 0 90.NONE <br /> VENT PRIMARY CONTAINMENT [3 1.STEEL 4,FIBERGLASS ■ 10.RIGID PLASTIC E] qQ.NONE <br /> pec 4ne. <br /> 171 99.OTHER(Si fy): <br /> VENT SECONDARY CONTAINMENT El 1.STEEL 4.FIBERGLASS [3 10.RIGIDPI�MC_13 90.NONE E3 99.OTHER(Specify): <br /> 464 <br /> VR PRIMARY CONTAINMENT 0 1.STEEL 4.FIBERGLASS ■ 10.RIGIDPLASTIC [3 90.NONE [1 9%.OTHER(Specify): 464p. <br /> 464 1 <br /> VR SECONDARY CONTAINMENT D LSTEEL 0 4.FIBERGLASS 0 10.RIGID PLASTIC 0 to NONE 0 99.OTHER(Specify): 464 <br /> 464h <br /> VENT PIPING TRANSITION SUMP TYPE 0 L SINGLE"I!:_02.D0_UBLEWALL­_[] 90.No�NE <br /> RISER PRIMARY CONTAINMENT1. 464J.STEEL 10 4.FIBERGLASS El 10,RIGID PLASTIC 90,NONE 0 99.OTHER(Specify)- <br /> 464 1. <br /> RISER SECONDARY CONTAINMENT 0 LSTEEL N 4.FIBERGLASS o io.RIGID PLASTIC go-NONE El 99.OTHER(Specify): 464k. <br /> FILL COMPONENTS IN -_ 4641, <br /> STALLED CM I-SPILLBUCKET 0 3.STRIKER PLATEIBOTTOM PROTECTOR 4.CONTAINM ENT SUMP 451ac. <br /> Effinjemballa Ile 13"'m a I <br /> _VIII. CORROSION PROTECTION <br /> W3 tft�El 9 0 M <br /> 1%,A to) <br />