My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 1:45:25 PM
Creation date
6/23/2020 6:57:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\J\JACK TONE\1501\PR0505264\FINAL JUDGMENT ON CONSENT 09-29-08.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> TEST DATE: 06/05/08 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2257402 <br /> AUSTIN,TEXAS 78759(512)451-6334 <br /> CLIENT: FLYING "J" INC SITE: FLYING J 0500075 <br /> Tank ID: DSL2 2 Tank manifolded: YES Bottom to top fill in inches: 96.0 <br /> Product: DIESEL Vent manifolded: No Bottom to grade in inches: <br /> Capacity in gallons: 15,000 Vapor recovery manifolded: NO Fill pipe length in inches: <br /> Diameter in inches: 96.00 Overfill protection: YES Fill pipe diameter in inches: <br /> Length in inches: 484 Overspill protection: YES Stage I vapor recovery: NONE <br /> Material: DW FIBERG Installed: ATG Stage II vapor recovery: NONE <br /> CP installed on: <br /> COMMENTS <br /> DSL 2 TANK RUNS DISP #21-25 <br /> 1 MAIN LINE AND 5 SATTELITE LINES <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: vAPORLESS <br /> Fluid volume in gallons: Model: LD2000 <br /> Tank water level in inches: S/N: 07031403 <br /> Test time: NOT Open time in sec: 7.00 <br /> Number of thermisters: TESTED Holding psi: 33 NOT <br /> Specific gravity: Resiliency cc: 275 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 20 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> Test time: <br /> Ullage volume: Material: DW FIBERG DW FIBERG DW FIBERG DW FIBERG <br /> Ullage pressure: Diameter(in): 3.0 3.0 3.0 3.0 <br /> Results: Length(ft): 300.0 15.0 15.0 15.0 <br /> Test psi: <br /> DATA FOR UTS-4T ONLY: Bleedback cc: <br /> Time of test 1: Test time(min): <br /> Temperature: NOT Start time: NOT NOT NOT NOT <br /> Flow rate(cfh): TESTED End time: TESTED TESTED TESTED TESTED <br /> Time of test 2: Final gph: <br /> Temperature: Result: <br /> Flow rate(cfh): Pump type: PRESSURE NONE NONE NONE <br /> Time of test 3: Pump make: RED JACKET GILBARCO GILBARCO GILBARCO <br /> Temperature: <br /> Flow rate(cfh): Impact Valves Operational: UNKNOWN <br /> COMMENTS COMMENTS <br /> IL I I I <br /> Printed 07/08/2008 08:48 ACRAMER <br />
The URL can be used to link to this page
Your browser does not support the video tag.