Laserfiche WebLink
ONIT NG SYSTEM CETIFIC ION <br /> F By All Jurisdictions Within the State of Califomia <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3 Title 23, Ca i omia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: FLYING J 0500075 City: RIPON CA Zip:95366 <br /> Site Address: 1501 N.JACK TONE RD Contact Phone No: 599-4141 <br /> Date of Testing/Service: 06/05/2008 <br /> Facility Contact Person: JOSE <br /> Make/Model of Monitoring System:TLS350 Work Order Number: 2257402 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: DSL 1 Tank ID: DSL 2 <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 303 FX Annular Space or Vault Sensor. Model: 303 <br /> X Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector. Model: FX1 DV X Mechanical Line Leak Detector. Model: LD2000 <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). ❑ Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: UbL 3 Tank ID: REG <br /> 71 In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 303 Annular Space or Vault Sensor. Model: 303 <br /> X Piping Sumprrrench Sensor(s). Model: 208 X Piping Sump/Trench Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector. Model: LD2000 X Mechanical Line Leak Detector. Model: MLD <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> Dispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s) Model:208 <br /> QX Shear Vaive(s). FRI Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> RI Dispenser Containment Sensor(s) Model:208X Dispenser Containment Sensor(s). Model:208 <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9THRU20 Dispenser ID: 21THRU30 <br /> XD Dispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s). Model:208 <br /> ❑X Shear Valve(s). X Shear Valve(s). <br /> Ill Dispenser Containment Float(s)and Chain(s). 10 Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up X❑Alarm history report <br /> Technician Name(print): RHOME DESBIENS Signature: <br /> Certification No.: 1938 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 06/05/2008 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />