My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2009-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 3:56:53 PM
Creation date
6/23/2020 6:57:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2011
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2009-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.�r <br />r7RFrF����n <br />UNIFIED PROGRAM CONSOLIDATED FORM <br />UNDERGROUND STORAGE TANK UrT Z O 1O <br />MONITORING PLAN - Pae I of 2) <br />q / g 0 g <br />TYPE OF ACTION ❑ 1. NEW PLAN ® 2. CHANGE OF INFORMATION V IRUNIVILN d HEALTH <br />490-1 <br />PLAN TYPE ❑ 1. MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. PERMIMERVICES <br />490-2 <br />(Check one item only) ® 2. THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S)- DIESEL TANK #1 & GASOLINETANKS #5- #6 <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) I I_I 1-1 1 1 1 1 1 1 <br />1 <br />BUSINESS NAME (Same as FACILITY NAME) Flying J Travel Plaza - #618 <br />3. <br />BUSINESS SITE ADDRESS 1501 N. Jack Tone Rd 103 CITY Ripon <br />104. <br />II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br />Testing, preventive maintenance, and calibration of monitoring equipment (e.g., sensors, probes, line leak detectors, etc.) must be performed at the frequency <br />specified by the equipment manufacturers' instructions, or annually, whichever is more frequent, and that such work must be performed by qualified personnel. <br />X23 CCR §2632, 2634_, 2638, 2641L_.__ <br />�❑ <br />MONITORING EQUIPMENT IS SERVICED ® 1. ANNUALLY 99. OTHER (Specify): ^49asb <br />III. MONITORING LOCATIONS <br />® 1. NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. ❑ 2. SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR §2632, <br />2634)4904 <br />IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S):' <br />1. CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR (INTERSTITIAL) SPACE(S) OR SECONDARY CONTAINMENT <br />490-5 <br />VAULT(S) WITH AUDIBLE AND VISUAL ALARMS. (23 CCR §2632,2634) <br />SECONDARY CONTAINMENT IS: ❑ a. DRY [E b. LIQUID FILLED F] c. PRESSURIZED ❑ d. UNDER VACUUM <br />490.6 <br />-_ -�-__ - ___-___--__-__--490- <br />PANEL MANUFACTURER: Veeder Root 490 7. MODEL #: TLS -350 <br />_ <br />0-9°-8 <br />LEAK SENSOR MANUFACTURER: Veeder Root 4119. MODEL #(S): 794380-303 <br />490-10 <br />❑ 2. AUTOMATIC TANK GAUGING (ATG) SYSTEM USED TO MONITOR SINGLE WALL TANK(S). (23 CCR §2643) <br />490-11 <br />PANEL MANUFACTURER: 490-12. MODEL #: <br />490-13 <br />-- -- IN -TANK PROBE MANUFACTURER w ------_ ---------_ _ __ a9aia.- MODEL #(S)----------- - _ - - - -- <br />------------ <br />440=15 <br />�-----^-_ ---------- _-__-_----___ _--_--_-_--_-_----_-_---- <br />LEAK TEST FREQUENCY: ❑ a. CONTINUOUS ❑ b. DAILY/NIGHTLY ❑ c. WEEKLY <br />_ <br />490-16 <br />❑ d. MONTHLY ❑ e. OTHER (Specify): <br />490.17 <br />---490-18 <br />PROGRAMMED TESTS: ❑ a. 0.1 g.p.h. ❑ b. 0.2 g.p.h. ❑ c. OTHER (Specify): <br />490-19 <br />❑ 3. MONTHLY STATISTICAL INVENTORY RECONCILIATION (23 CCR §2646.1): <br />490-20 <br />❑ 4. WEEKLY MANUAL TANK GAUGING (MTG) (23 CCR §2645). TESTING PERIOD: [:]a. 36 HOURS ❑ b. 60 HOURS <br />490-21 <br />490.22 <br />❑ 5. TANK INTEGRITY TESTING (23 CCR §2643.1): <br />490-23 <br />TEST FREQUENCY: ❑ a. ANNUALLY ❑ b. BIENNIALLY ❑ c. OTHER (Specify): <br />490-24 <br />490-25 <br />® 99. OTHER (Specify): VISUAL DONE DAILY <br />490-26 <br />490-27 <br />V. PIPE MONI'T'ORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all that apply) <br />® 1. CONTINUOUS MONITORING OF PIPE/ PIPING SUMP(S) AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND <br />ago-zs <br />VISUAL ALARMS. (23 CCR §2636) <br />SECONDARY CONTAINMENT IS: ®a. DRY ❑b. LIQUID FILLED ❑c. PRESSURIZED ❑d. UNDER VACUUM <br />490-29 <br />PANEL MANUFACTURER: Veeder Root 491-30 MODEL #: TLS -350 <br />490-31 <br />490-32 MODEL #(S): 794380-208 - -- <br />LEAK_ SENSOR MANUFACTURER: Veeder Root <br />490-33 <br />--____ _ _ _ _ __-_----____-- <br />PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP (i.e., TURBINE) SHUTDOWN. ® a. YES ❑ b. NO <br />490-34 <br />FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a. YES ❑ b. NO <br />490-35 <br />® 2. MECHANICAL LINE LEAK DETECTOR (NH.LD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF <br />PRODUCT FLOW WHEN IS DETECTED CCR_J2636)____ <br />490-36 <br />_A_LE_A_K _(23 <br />- MLLD MANUFACTURER(S): RED JACKET 490.37 MODEL #(S): FX1DV & FX1V <br />490-38 <br />❑ 3. ELECTRONIC LINE LEAK DETECTOR (ELLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS (23 CCR §2636) <br />490-39 <br />ELLD MANUFACTURER(S) 49040 MODEL #(S): <br />ago -0-1 <br />PROGRAMMED IN LINE LEAK TEST: ❑ 1. MINIMUM MONTHLY 0.2 g.p.h. ❑ 2. MINIMUM ANNUAL 0.1 g.p.h. ----- <br />490-42 <br />ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES ❑ b. NO <br />49043 <br />ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES ❑ b. NO <br />490-44 <br />❑ 4. PIPE INTEGRITY TESTING 49045 <br />TEST FREQUENCY ❑ a. ANNUALLY ❑ b. EVERY 3 YEARS ❑ c. OTHER (Specify) 490-46 490-47 <br />❑ 5. VISUAL PIPE MONITORING. <br />490-48 <br />FREQUENCY ❑ a. DAILY ❑ b. WEEKLY ❑ c. MIN. MONTHLY & EACH TIME SYSTEM OPERATED" <br />490-49 <br />* Allowed for monitoring of unburied einergency generator fuel piping only per HSC §25281.5(b)(3) <br />❑ 6. SUCTION PIPING MEETS EXEMPTION CRITERIA [23 CCR §2636(a)(3)]. <br />490-50 <br />7. NO REGULATED PIPING PER HEALTH AND SAFETY CODE, DIVISION 20, CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br />490-51 <br />❑ 99. OTHER (Specify) <br />490-52 <br />490-53 <br />UPCF UST -D (12/2007) <br />