Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN - Pae 1 of 21 <br />TYPE OF ACTION [:11. NEW PLAN ® 2. CHANGE OF INFORMATION <br />490.1 <br />PLAN TYPE ❑ 1. MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. <br />490-2 <br />(Check one item only) E 2. THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(- GAROLINR TANK #4 <br />1. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) I I I -I I 1 1-11 <br />BUSINESS NAME (Same as FACILITY NAME) Flying J Travel Plaza - #618 <br />3. <br />BUSINESS SITE ADDRESS 1501 N. Jack Tone Rd 103. <br />CITY Ripon <br />104. <br />II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br />Testing, preventive maintenance, and calibration of monitoring equipment (e.g., sensors, probes, line leak detectors, etc.) must be performed at the frequency <br />specified by the equipment manufacturers' instructions, or annually, whichever is more frequent, and that such work must be performed by qualified personnel. <br />23 CCR 2632, 2634, 2638 2641 <br />MONITORING EQUIPMENT IS SERVICED E 1. ANNUALLY ❑ 99. OTHER (Specify): <br />4900.-3b <br />III. MONITORING LOCATIONS <br />E 1. NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. ❑ 2. SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR §2632, <br />2634)490-4 <br />IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING ETHOD(S); <br />E 1. CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR (INTERSTITIAL) SPACE(S) OR SECONDARY CONTAINMENT <br />490-5 <br />VAULT(S) WITH AUDIBLE AND VISUAL ALARMS. (23 CCR §2632,2634) <br />SECONDARY CONTAINMENT IS: ❑ a. DRY E b. LIQUID FILLED ❑ c. PRESSURIZED El d. UNDER VACUUM <br />490.6 <br />_-__-_-_--------------- ----------------------------- <br />PANEL MANUFACTURER: Veeder Root 491. MODEL #: TLS -350 <br />490-8 <br />- - -- - - <br />LEAK SENSOR MANUFACTURER: Veeder Root 49o-9. ; MODEL #(S): 794380-303 <br />490-10 <br />❑ 2. AUTOMATIC TANK GAUGING (ATG) SYSTEM USED TO MONITOR SINGLE WALL TANK(S). (23 CCR §2643) <br />490-11 <br />PANEL MANUFACTURER: 490-12. MODEL #: <br />490-13 <br />IN -TANK PROBE MANUFACTURER: 0-90-14- MODEL #(S)^ <br />490-15 <br />-_-__-__- ___- _----------------- ___- _-_-__---�---- _--- _ __---__-_--------------------- -__------------ <br />LEAK TEST FREQUENCY: ❑ a. CONTINUOUS ❑ b. DAILYINIGHTLY ❑ c. WEEKLY <br />490-16 <br />❑ d. MONTHLY ❑ e. OTHER (Specify): <br />490-17 <br />-------------------------------- ------------- - - - - - - - - --._.-----_._•-.-._._--- - - - --- - - - -- --- - - - - - - - - - - - - - - - - - -------------------- <br />PROGRAMMED TESTS: ❑ a. 0.1 g.p.h. ❑ b. 0.2 g.p.h. ❑ c. OTHER (Specify): <br />490-18 <br />490-19 <br />❑ 3. MONTHLY STATISTICAL INVENTORY RECONCILIATION (23 CCR §2646.1): <br />490-20 <br />❑ 4. WEEKLY MANUAL TANK GAUGING (MTG) (23 CCR §2645). TESTING PERIOD: E] a. 36 HOURS El b. 60 HOURS <br />490-21 <br />90 22 <br />5. TANK INTEGRITY TESTING (23 CCR §2643.1): <br />490-23 <br />OTHER (Si <br />TEST FREQUENCY: ❑ a. ANNUALLY El b. BIENNIALLY [I c. pec <br />Q �): <br />490-24 <br />490.25 <br />® 99. OTHER (Specify): VISUAL DONE DAILY <br />490.26 <br />0-90-27 <br />V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Cheek all that apply) <br />® 1. CONTINUOUS MONITORING OF PIPE/ PIPING SUMP(S) AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND <br />90-2s <br />490-28"- <br />VISUAL ALARMS. (23 CCR §2636) <br />VISUAL <br />SECONDARY CONTAINMENT IS: Ea. DRY ❑b. LIQUID FILLED []c.PRESSURIZED ❑d. UNDER VACUUM <br />- <br />490-29 <br />PANEL MANUFACTURER: Veeder Root 490-30 <br />MODEL #: TLS -350 -- <br />490-31 <br />------------------------•--•-------------_ _ - - - -- - - - - - _------- --- - - - ----- <br />LEAK SENSOR MANUFACTURER: Veeder Root 490-32 <br />-- - -- - - - - - - - - - - - - ----- <br />MODEL #(S): 794380-208 -�� <br />490.33 <br />PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP (i.e., TURBINE) SHUTDOWN. E a. YES ❑ b. NO <br />490.34 <br />FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. E a. YES ❑ b. NO <br />490-35 <br />2. MECHANICAL LINE LEAK DETECTOR (MLLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF <br />PRODUCT FLOW WHEN A LEAK IS DETECTED 23 CCR §2639 _ ------- _ <br />- _ <br />490.36 <br />_ _ <br />MLLD MANUFACTURER(S): FE PETRO 490-37 MODEL #(S): MLD <br />490-38 <br />❑ 3. ELECTRONIC LINE LEAK DETECTOR (ELLD) THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS (23 CCR §2636) <br />- - -- - ------------ <br />490-39 <br />------_- _ --- <br />_ ELLD MANUFACTURER(S) 49040• { MODEL #(S): __-------- - ---- _____- <br />49041 <br />PROGRAMMED IN LINE LEAK TEST: 0+1. MINIMUM MONTHLY 0.2 g.p.h. ❑ 2. MINIMUM ANNUAL 0.1 g.p.h. <br />490-42 <br />ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES ❑ b. NO <br />49043 <br />ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES ❑ b. NO <br />49044 <br />4. PIPE INTEGRITY TESTING 49045 <br />TEST FREQUENCY ❑ a. ANNUALLY ❑ b. EVERY 3 YEARS ❑ c. OTHERS i 490.46 490-47 <br />❑ 5. VISUAL PIPE MONITORING. <br />490-48 <br />FREQUENCY ❑ a. DAILY ❑ b. WEEKLY ❑ c. MIN. MONTHLY & EACH TIME SYSTEM OPERATED° <br />490-49 <br />* Alimed for monitoring of unburied emergency erator fuel piping only HSC §25281.5(b)(3 <br />❑ 6. SUCTION PIPING MEETS EXEMPTION CRITERIA [23 CCR §2636(a)(3)]. <br />490-50 <br />❑ 7. NO REGULATED PIPING PER HEALTH AND SAFETY CODE, DIVISION 20, CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br />490-51 <br />El 99. OTHER (Specify) <br />490-52 <br />490.53 I <br />UPCF UST -D (12/2007) 7/23 <br />