Laserfiche WebLink
Materials:" OPW Stainless Steel <br /> Hose: 322 Stainless Steel <br /> Flexible Connectors <br /> Wire Braid: 304 Stainless Steel l <br /> Stainless Steel Flexible Connectors provide <br /> Pipe Nipples: SCH.#80 Stainless Steelflexibility in the installation and operation <br /> Swivel:Viton'/Buna Seals of fuel piping systems. Flexible Connectors <br /> can be used as a convenient means of <br /> Features: connecting piping to pumps and dispensers <br /> and throughout the piping systems where <br /> ♦ Maximum working pressure: 150 PSIG(10 bar) I connections and changes of direction are <br /> ♦ Service temperature range:-320 F to 1500 F necessary. Flexible Connectors dampen the <br /> effect of ground and/or piping movement. <br /> ♦ Minimum burst pressure 750 PSIG(52 bar) All <br /> All stainless steel construction ensures long <br /> ♦ Inherent hoop strength of convoluted hose service life and corrosion protection.Flexible <br /> allows full vacuum service , Connectors are rated for 150 psig(10 bar) <br /> working pressure,as well as for full vacuum <br /> ULCIORD-0536-1998 and UL2039 service.Compatible with diesel,gasoline, <br /> (underground and above ground installations) ti.. methanol,ethanol and MTBE.Available as <br /> 160° , Male by Male and Male Swivel by Male, <br /> 90�--I Male 90 and Easy Clamp Connectors. <br /> r FLEXIBLE LENGTH JSfr <br /> 41 NAFTA approved,can be used in any country. <br /> OFFSET \ p <br /> 45' <br /> LATERAL OFFSET ANGULAR <br /> Ordering Specifications and Dimensions <br /> Max.Angular Max.Lateral Min.Bend <br /> MALE x MALE Bending(Degree) Offset Radius <br /> Model# NPT Thread Size Len th Hose O.D. Static Intermittent Static Installation Intermittent Flexln Static Installation Ysrd Flexing <br /> In. mm In. mm In. mm Position Flexing in. i mm in. mm in. mm in. mm <br /> FC075-MM12 .75 19.1 12 304.8 1.0 25.4 100' 55' 2.0 50.8 1.2 30.5 4.5 114.3 8 203.2 <br /> FC10-MM12 1 25.4 12 304.8 1.3 33.0: 70' 45' 1.4 35.6 0.9 22.9 5.5 139.7 9 228.6 <br /> FC10-MM18 1 25.4 18 457.2 1.3 33.0' 135' 85' 4.5 114.3 2.1 53.3 5.5 139.7 9 228.6 <br /> FC10-MM24 1 25.4 24 609.6 1.3 33.0 180' 125' 8.6 218.4 2.1 53.3 5.5 139.7 9 228.6 <br /> FC15-MM12 1.5 38.1 12 304.8 2.25 57.2 90' 35' 1.5 38.1 .75 19.1 4 101.6 11 279.4 <br /> FC15-MM14 1.5 38.1 14 355.6 2.25 57.2 90' 35' 1.5 38.1 .75 19.1 4 101.6 11 279.4 <br /> FC15-MM18 1.5 38.1 18 457.2 2.25 57.2 150' 55' _4.0 101.6 1.5 38.1 4 101.6 11 279.4 <br /> FC15-MM24 1.5 38.1 24 609.6 2.25 57.2 180' 85' 8.0 203.2 2.75 69.9 4 101.6 11 279.4 <br /> FC15-MM30 1.5 38.1 30 762.0 2.25 57.2 180' 115' 12.0 304.8 2.75 69.9 4 101.6 11 279.4 <br /> FC20-MM12 2 50.8 12 304.8 2.72 69.1 75' 30' 1.5 38.1 0.60 15.2 5 127.0 12 304.8 <br /> FC20-MM14 2 50.8 14 355.6 2.72 69.1 75' 30' 1.5 38.1 0.60 15.2 5 127.0 12 304.8 <br /> FC20-MM18 2 50.8 18 457.2 2.72 69.1 120' 50° 3.0 76.2 1.5 38.1 5 127.0 12 304.8 <br /> FC20-MM24 2 50.8 24 609.6 2.72 69.1 180' 75° 7.0 177.8 3.0 76.2 5 127.0 12 304.8 <br /> FC20-MM36 2 50.8 36 914.4 2.72 69.1 180' 105' 12.0 304.8 3.0 76.2 5 127.0 12 304.8 <br /> FC30-MM18 3 76.2 18 457.2 3.97 100.8 70' 35' 2.0 50.8 1.0 25.4 8 203.2 16 406.4 <br /> FC30-MM24 3 76.2 24 609.6 3.97 100.8 110' 55' 4.8 121.9 2.5 63.5 8 203.2 16 406.4 <br /> Approvals and The UL and ULC rating for Us UL ULC Approval Testing std. <br /> the OPW Flex Connectors are OPW Product Classification Approval ORD536,ASME and CSA B51 <br /> Listings rated for both UST and AST s CIP <br /> applications.Refer to the FC075 MVTV UST ONLY UST and AST $ C �� us <br /> summary chart on the right. FC10 MVTv UST ONLY UST and AST <br /> FC15 1%" QLWv UST and AST UST and AST <br /> FC20 2" 2__ UST and AST UST and AST <br /> FC30 <br /> MT <br /> UST ONLY UST and AST <br /> OR tnelmg Components 9393 Princeton-Glendale Road we- Hamilton,Ohio USA 45011 •Phone:(800)422-2525 Fax:(800)421-3297 123 <br />