0 JECEIVED <br /> SWRCB,January 2002 SEP, 10 2014 Page of <br /> 7. UNDER-DISPENSER CONTAINMENT U <br /> Test Method Developed By: P UDC Manufacturer x Industry Stan ar MIT <br /> r <br /> Other(Spec) <br /> Test Method Used: 11 Pressure C:l Vacuum X Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon Incon TS-STS Tester Equipment Resolution: +/-0.002 <br /> UDC# 22 Sat UDC# 22 Main UDC# 23 Sat UDC# 23 Main <br /> UDC Manufacturer: Unknown Unknown Unknown Unknown <br /> UDC Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 30" 30" 30" 30" <br /> Height from UDC Bottom to Top 13" 14" 13" 14" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 91. 91, 91. 91, <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Dry Dry Dry Dry <br /> testing: <br /> Portion of UDC Tested' 17" 18" 17" 18" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes [kNo [INA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- <br /> safe shutdown? Yes ❑No Cl NA 11 Yes [I No El NA ❑Yes ❑No LINA ❑Yes ❑No [INA <br /> Was fail-safe verified to be <br /> id <br /> operational? Yes 1-1No [INA [-I ❑ F1NA Yes No ❑NA Yes ❑No NA ❑Yes ❑No [INA <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: 11:14 am 11:33 am 9:59 am 9:43am 10:57 am 11:14 am 11:14 am 11:33 am <br /> Initial Reading(RI): 5.4977" 5.4931" 6.7729" 6.7720" 3.5309" 3.5305" 5.4303" 5.4320" <br /> Test End Time: 11:29 am 11:48 air 10:14 am 9:58 am 11:12 am 11:29 am 11:29 am 11:48 air <br /> Final Reading(RF): 5.4976" 5.4924" 6.7730 6.7729" 3.5308" 3.5304" 5.4319" 5.4326" <br /> Test Duration: 15 Minutes Each 30) 15 Minutes Each 30 15 Minutes Each 30 15 Minutes Each (30 <br /> Change in Reading(RF-RI): -0.0001 1 -0.0007 0.0001 10.0009 0.0001 -0.0001 0.0016 0.0006 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" +/-0.002" +/-0.002" +/-0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result: ® Pass ' ❑Fail 09 Pass ❑Fail ® Pass ❑Fail ® Pass U Fail <br /> Was sensor removed for testing? ❑Yes ❑No 9 NA ❑Yes ❑No ❑NA E Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and ❑yes [----]No ®NA 11 Yes El No NA F-1 Yes El No 11 NA Yes Ll No 11 NA <br /> n <br /> verified functional after testin ? <br /> Comments-(include information on repairs made prior to testing, and recommended folloiv-up for failed tests) <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />