My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2014-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2021 4:36:01 PM
Creation date
6/23/2020 6:57:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2015
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2014-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
382
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 3ECEIVED <br /> SWRCB,January 2002 SEP 2014Page of <br /> 7. UNDER-DISPENSER CONTAINMENT(UDC <br /> Test Method Developed By: ❑UDC Manufacturer ❑Industry Standard gineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Incon Incon TS-STS Tester Equipment Resolution: +/-0.002 <br /> NEMENEENNEMEMMMEM <br /> UDC# 26 Sat UDC# 26 Main UDC# 27 Sat UDC# 27 Main <br /> UDC Manufacturer: Unknown Unknown Unknown Unknown <br /> UDC Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 30" 30" 30" 30" <br /> Height from UDC Bottom to Top 13" 13" 14" 14" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 91, 91, 8 91, <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Dry Dry Dry Dry <br /> testing: <br /> Portion of UDC Tested' 17" 17" 17" 17" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No 9 NA ❑Yes ❑No ®NA ❑Yes ❑No X NA ❑Yes []No X NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- ❑Yes ENo X NA ❑Yes ❑No 9 NA ❑Yes ❑No 9 NA ❑Yes ❑No X NA <br /> safe shutdown?' <br /> Was fail-safe verified to be <br /> operational?* 11Yes ❑No KNA ❑Yes L1No ©NA ❑Yes ❑No O7 NA ❑Yes ❑No CX NA <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: 2:51 prn 3:08 m 1:57 pm 2:15 m 3:08 m 3:24 m 2:51 m 3:08 pm <br /> Initial Reading(RI): 3.0793" 3.0789" 4.1800" 4.1797" 4.9715" 4.9702" 7.0040" 7.0038 <br /> Test End Time: 3:07 pm 1 3:23 prn 2:12 pm 2:30pm 3:23 prn 3:39 pm 3:07 pm 3:23 pm <br /> Final Reading(RF): 3.0790" 3.0786" 4.1797" 4.1795" 4.9723" 4.9710" 7.0041" 7.0034" <br /> Test Duration: 15 Minutes Each 30 15 Minutes Each 30 15 Minutes Each 30 15 Minutes Each 30 <br /> Change in Reading(RF-Ri): -0.0003 -0.0003 -0.0003 -0.0002 0.0008 0.0008 0.0001 -0.0004 <br /> Pass/Fail Threshold or Criteria: +/-0.002'17+/-0.002" +/-0.002" +/-0.002 +/-0.002" 1 +/-0.002" +/-0.002" 1 +/-0.002" <br /> Test Result: ® Pass ❑Fail ® Pass ❑Fail ® Pass' 0 Fail ® Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes ❑No 9 NA X Yes ❑No ❑NA 9 Yes ❑No ❑NA X Yes ❑No ❑NA <br /> Was sensor properly replaced and ❑Yes ❑No I►k NA 9 Yes ❑No ❑NA X Yes ❑No ❑NA 9 Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 'If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />