Laserfiche WebLink
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Pilot-Flying J#618 Bldg No.-1501 <br /> Site Address: 1501 N. Jack Tone Road city: Ripon Zip: 95366 <br /> Facility Contact Person: Holly Marlowe Contact Phone No.:( 9 t 599-4141 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS-350 Date of Testing/Servicing: 5 / 14/ 2 0 1 4 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the approlgriate boxes to indicatespecific a ui ment I sl ected/serviced: <br /> Tank ID: T-5 Premium 91 12,000 Gallons. Tank ID: T-6 Auto Diesel 12,000 Gallons. <br /> x In-Tank Gauging Probe. Model: 647390-109 In-Tank Gauging Probe. Model: 843790-109 <br /> x Annular Space or Vault Sensor. Model: 794380.303 z Annular Space or Vault Sensor. Model: 794380-303 <br /> x Piping Sump/Trench Sensor(s). Model: 794380-20e x Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> Fill Sump Sensor(s). Model: NIA Fill Sump Sensor(s). Model: NIA <br /> x Mechanical Line Leak Detector. Model: vaponess LD-2000 x Mechanical Line Leak Detector. Model: FXIDV <br /> Electronic Line Leak Detector. Model: N/A Electronic Line Leak Detector. Model: NIA <br /> x Tank Overfill/High-Level Sensor. Model: OPW Flapper r Tank Overfill/High-Level Sensor. Model: DPW Flapper <br /> Others ci ui ent and model in Section E on Pae 2). Others ci ui ment and model in Section E on Page 2). <br /> Tank ID: NIA Tank ID: NIA <br /> In-Tank Gauging Probe. Model: NIA In-Tank Gauging Probe. Model: NIA <br /> Annular Space or Vault Sensor. Model: NIA Annular Space or Vault Sensor. Model: NIA <br /> Piping Sump/Trench Sensor(s). Model: NIA Piping Sump/Trench Sensor(s). Model: NIA <br /> Fill Sump Sensor(s). Model: NIA Fill Sump Sensor(s). Model: NIA <br /> Mechanical Line Leak Detector. Model: NIA Mechanical Line Leak Detector. Model: NIA <br /> Electronic Line Leak Detector. Model: NIA Electronic Line Leak Detector. Model: NIA <br /> Tank Overfill/High-Level Sensor. Model: NIA Tank Overfill/High-Level Sensor. Model: NIA <br /> Others a equieMent and model in Section E on Pae 2). Others i!y 2quippent and model in Section E on Pae 2). <br /> Dispenser ID: 13 Dispenser ID: 14-15 <br /> " Dispenser Containment Sensor(s). Model: — -2cle Dispenser Containment Sensor(s). Model: 7943M20e <br /> " Shear Valve(s). Shear Valve(s). <br /> Disp2nser Containment Floats and Chain(s). Disp2nser Containment Floats and Chains. <br /> Dispenser ID: 16 Dispenser ID: 19 Main <br /> Dispenser Containment Sensor(s). Model: 794380-208 " Dispenser Containment Sensor(s). Model: 794380-208 <br /> " Shear Vahre(s). " Shear Valve(s). <br /> Dis nser Containment Floats and Chains. Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: 19 sat Dispenser ID: 20 Main <br /> " Dispenser Containment Sensor(s). Model: 7943e0 toe = Dispenser Containment Sensor(s). Model: 794390-208 <br /> " Shear Valve(s). " Shear Valve(s). <br /> Disp2nser Containment Floats and Chains Disp2nser Containment Floats and Chains. <br /> If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced In accordance with the manufacturers' <br /> guidelines. Attached to this Certification Is Information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): x System set-up x Alarm history report <br /> Technician Name(print): Edwin Coreas Signature: <br /> Certification No.: 834020 License.No.: 804431 <br /> Testing Company Name: Jones Covey Group, Inc. Phone No.: 88( 8 ) 972-7581 <br /> Testing Company Address: 9595 Lucas Ranch Rd.#100 Rancho Cucamonga CA,91730 Date of Testing/Servicing: 5 / 14/ 2 0 1 4 <br /> Monitoring System Certification Page of 12107 <br />