Laserfiche WebLink
IFIED PROGRAM CONSOLIDATED FAW <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(one form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections 1,11,111,IV,and IX below) 430 <br /> ❑ 1•NEW PERMIT N 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430a I DATE EXISTING UST DISCOVERED: 430b <br /> L FACMITY INFORMATION <br /> FACILITY ID#(Agency Use Only) 1 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 <br /> Flying J Travel Plaza-#618 <br /> BUSINESS SITE ADDRESS 103 CITY 104 <br /> 1501 N. Jack Tone Rd Ripon <br /> II.TANK DESCRIPTION <br /> TANK ID# 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> T ®1.A STAND-ALONE TANK <br /> T-4TA A ®E ® S Z& 5 Xerxes [12.ONE IN A COMPARTMENTED UNIT. <br /> Complete one pMe for each compartment in the unit. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> 12/94 trk A4 12,000 E <br /> M.TANK USE AND CONTENTS <br /> TANK USE N la.MOTOR VEHICLE FUELING ❑ ]b.MARINA FUELING ❑ Ic.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 439a <br /> CONTENTS PETROLEUM: N la.REGULAR UNLEADED ❑ ]c.MIDGRADE UNLEADED ❑ 1b.PREMIUM UNLEADED 440 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 440a <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 4406 <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL N 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL N 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 444a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL N 3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify): 445a <br /> OVERFILL PREVENTION N 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT ® 3.FILL TUBE SHUT-OFF VALVE 452• <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING.CONSTRUCTION <br /> PIPING CONSTRUCTION ❑1.SINGLE-WALLED N 2.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE ® 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR§2636(n)(3)] 458 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL N 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT ❑ L STEEL N 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGIDPLASTIC 4646 <br /> ❑ 90.NONE ❑ 95,UNKNOWN ❑ 99.OTHER(Specify): 464c <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE N 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464d <br /> VI.VENT,VAPOR.RECOVERY(VR)AND RISER:/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL N 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464e <br /> 464e1 <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL N 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464f <br /> 464171 <br /> VR PRIMARY CONTAINMENT ❑ I.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90,NONE ❑ 99.OTHER(Specify) 4648 <br /> 464SI <br /> VR SECONDARY CONTAINMENT ❑ L STEEL N 4.FIBERGLASS ❑ 10,RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464h <br /> 464hl <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL N 90.NONE 4641. <br /> RISER PRIMARY CONTAINMENT N 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4641 <br /> 464'1 <br /> RISER SECONDARY CONTAINMENT ❑ 1.STEEL N 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464k <br /> 464kl <br /> FILL COMPONENTS INSTALLED ® 1.SPELL BUCKET N 3,STRIKER PLATE/BOTTOM PROTECTOR N 4.CONTAINMENT SUMP 45la-c <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469a <br /> CONSTRUCTION MATERIAL ❑ L STEEL N 4.FIBERGLASS ❑ 10.RIGIDPLASTIC ❑ 99.OTHER(Specify) 469b-c <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT N 6.ISOLATION 448• <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> and in full compliance with legal requirements. <br /> a 470. <br /> APP URE DATE S,_/�^16. t <br /> 1 T NAME prin 471' APPLICANT TITLE �', <' 47z. <br /> .40 Joey Cupp Environment Management e <br /> UPCF UST-B-1/23 "�'` Rev.(12/2007) <br />