Laserfiche WebLink
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION:" -f <br /> For Use By All Jurisdictions Within the State of Calfomia <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,`C#11fDm1&Code hof <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information Flying J#618 <br /> Facility Name: y g Bldg.No.: <br /> Site Address: 1501 N.Jack Tone Rd. City. Ripon, CA. Zip: 95366 <br /> Facility Contact Person: Manager Contact Phone No.:( 09 ) 599-4141 <br /> Make/Model of Monitoring System: TLS 350 Date of Testing/Servicing:0 5 /0 3/ 2 0 1 7 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate Ific 2quipment insl iected/serviced: <br /> Tank ID: Ts B10 Diesel 20k Tank ID: Tau Sump <br /> )C In-Tarn Gauging Probe. Model: 846391-log ❑ In-Tank Gauging Probe. Model: N/A <br /> Annular Space or Vault Sensor. Model: 794380.303 ❑ Annular Space or Vault Sensor. Model: N/A <br /> m Piping Sump/Trench Sensor(s). Model: 794380.208 wi 794380-304 xp Piping Sump/Trench Sensor(s). Model: 794380-208 wi 794380-304 <br /> ,c Fill Sump Sensor(s). Model: 794380-208 wi 794380-304 ❑ FII Sump Sensor(s). Model: NSA <br /> ❑ Mechanical Line Leak Detector. Model: N/A ❑ Mechanical Line Leak Detector. Model: N/A <br /> ❑ Electronic Line Leak Detector. Model: N/A ❑ Electronic Line Leak Detector. Model: N/A <br /> rd❑ Tank Overfill/High-Level Sensor. Model: OPW Flapper ❑ Tank Overfill/High-Level Sensor. Model: N/A <br /> ❑ Other equipment and model in Section E on Page 2). ❑ Others equipment MLe and model in Section E on PaQe 2). <br /> Tank ID' North Transition Sump Tank ID: South Transition Sump <br /> ❑ In-Tank Gauging Probe. Model: N/A ❑ in-Tank Gauging Probe. Model: N/A <br /> ❑ Annular Space or Vault Sensor. Model: NIA ❑ Annular Space or Vault Sensor. Model: N/A <br /> Piping Sump/Trench Sensor(s). Model: 794380-208 w1794380-304 m Piping Sump/Trench Sensor(s). Model: 794380-208 wi 794380-304 <br /> ❑ Fill Sump Sensor(s). Model: NIA ❑ Fill Sump Sensor(s). Model: N/A <br /> ❑ Mechanical Line Leak Detector. Model: N/A ❑ Mechanical Line Leak Detector. Model: N/A <br /> ❑ Electronic Line Leak Detector. Model: NIA ❑ Electronic Line Leak Detector. Model: N/A <br /> ❑ Tank Overfill/High-Level Sensor. Model: NSA ❑ Tank Overfill/High-Level Sensor. Model: N/A <br /> ❑ Other u!ppent a and model in Section E on Pa 2). ❑ 2guipMerrt and model in Section E on Pa 2). <br /> Dispenser 10: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Digp2aw Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Disperser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chains. ❑ Dispenser Containment Floats and Chains. <br /> Dispenser ID: DispenserID: <br /> ❑ Dispenser Containment Sensor(s). Model: 1 ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ nser Containment Floats and Chains ❑ Dispenser Containment Floats and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified In this document was Inspectedifserviced In accordance with the manufacturers' <br /> guidelines. Attached to this Certification Is information(e.g.manufacturers'checklists)necessary to verify that this information Is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,l have also attached a <br /> copy of the report;(check ap that y). 19 System set-up ®Alarm history report <br /> Technician Name(print): James Blaine Signature:_ - <br /> Certification No.: V-R##-B43163 i Ick#-8469775 License. 804431 <br /> Testing Company Name: Jones Covey Group, Inc. phone No.; 88( 8 ) 972-7581 <br /> Testing Company Address: 9595 Lucas Ranch Rd.#100 Rancho Cucamonga CA,91730 Date of TestingrSeroicing:0 5 /03/ 2 0 1 7 <br /> Monhoring System Certification Pop of 12107 <br />