Laserfiche WebLink
SA N X10 A Q U I N Environmental Health Department <br /> -- ivvu1%� J Y-- <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FLYING J TRAVEL PLAZA#618* 1501 N JACK TONE RD,RIPON May 03,2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b)Failure to maintain monitoring,maintenance,and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site.The facility failed to document <br /> the 1-8:diesel 2 annular setup data warning alarm that occurred on 4/13/2018. These records shall be maintained <br /> on site for at least three years. Monitoring records include:(1)date and time of all monitoring or sampling;(2) <br /> monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4)results of <br /> sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring equipment, <br /> ground water elevations,or other test results;(6)results of inventory readings and reconciliations. Immediately <br /> locate and maintain all maintenance and monitoring records for the last three years on site and submit a statement <br /> on how the alarm was addressed. <br /> This is a minor violation. <br /> 204 CCR 2712(i)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a repeat violation,Class II. <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br /> Work orders from Jones Covey were found on site for maintenance work that was conducted on 12/5/2017, <br /> 1/22/2018,and 417/2018,which indicated that leak detectors and sensor were replaced.No notification were made <br /> to EHD for these like for like replacements and the conditions for the no permit required work policy was not <br /> followed.On 1123/2018,Isaac Garcia contacted EHD about information regarding leak detector replacement and <br /> EHD policy was submitted to him.No further correspondence was made.Emergency repairs relating to UST system <br /> monitoring and release detection may be performed by a properly licensed,trained,and certified contractor <br /> pursuant to the EHD's policy and a permit obtained within one business day from the EHD.All other repairs must <br /> have a permit submitted to and approved by the EHD prior to beginning work.Immediately obtain a permit from the <br /> END for the above mentioned repairs.A"failure to obtain a permit'penalty applies.Submit proof of correction to the <br /> EHD. <br /> This is a minor violation. <br /> 209 CCR 2715(c)Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the December 2017 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include:three L29:Disp 19 Satellite fuel alarms for 11/2112017. During the monthly inspection,the <br /> designated operator shall review the alarm history for the previous month,check that each alarm was documented <br /> and responded to appropriately,and attach a copy of the alarm history with documentation taken in response to any <br /> alarms to the monthly report Ensure that designated operators performing monthly inspections at this facility are <br /> including all of the required information on the reports. <br /> This is a repeat violation,Class II. <br /> FA0006672 PRO505264 SCO01 05/03/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 6 Underground Storage Tank Program OR <br /> 1868 E.Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.corn <br />