Laserfiche WebLink
Environmental Health Department <br /> SAN JOAQUIN <br /> —C O U N T Y— Linda Turkatte, RENS, Director <br /> Kasey Foley,REHS,Assistant Director <br /> c�L,Fda•?`°' Greatness grows dere. PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco,REHS,RD[ <br /> Rodney Estrada,REHS <br /> Willy Ng,REHS <br /> Muniappa Naidu,REHS <br /> May 17,2018 <br /> ROBERT SILLS <br /> JONES COVEY GROUP, INC. <br /> 9595 LUCAS RANCH RD#100 <br /> RANCHO CUCAMONGA,CA 91730 <br /> Re: FLYING J TRAVEL PLAZA#618" SR0079094 <br /> 1501 N JACK TONE RD <br /> RIPON,CA 95366 <br /> The San Joaquin County Environmental Health Department(EHD)has completed the review of the <br /> application for a permit to replace a line leak detector with a new model 99-LD2000E on Tank 2,to replace <br /> an annular sensor with Veeder Root sensor 303 on Tank 2,to replace a line leak detector with a new mode <br /> 99-LD2000E on Tank 3,and to replace FE Petro with Red Jacket FX1 D on Tank 4 on the underground <br /> storage tank(UST)system at the above noted address. This work(with exception of work at Tank 4)was <br /> completed between December 2017 and April 2018, no EHD notification/permit was provided.The permit <br /> has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Elena Manzo at(209)953-7699 to arrange the following appointments(a 48-hour notice is <br /> required for inspection appointments). Please be aware that inspections for emergency work must be <br /> scheduled within five days of permit approval. <br /> • Sensor functionality: Functionality of the monitoring system must be verified to ensure that <br /> monitoring has been restored to meet the requirements of Title 23 California Code of Regulations <br /> and the Health&Safety Code. Monitoring system functionality and leak detector testing for Tanks <br /> 3 and 4 was verified during the monitoring system certification conducted on May 3, 2098 and <br /> May 4, 2098. <br /> • Leak detector test.Leak detector on Tank 4(87-octane)must be tested to confirm that the <br /> device can detect a leak of 3 gallons per hour at 90 psi. <br /> 4. If concrete was broken near the Tank 2,Tank 3,and Tank 4 tank,a secondary containment test mus <br /> be performed on the Tank 2,Tank 3,and Tank 4 tank once concrete is poured in accordance with the <br /> manufacturer's guidelines. <br /> 1868 E. Hazelton Avenue I Stockton,California 952051 T 209 468-34201 F 209 464-0138 1 www.sjcehd.com <br />