S A N a10 A Q U I N Environmental Health Department <br /> c0UN.TY—.__ <br /> ergo�ind toa k�P�©gralns � <br /> IT <br /> �. <br /> w. ..,� .=tea <br /> Facility Name: Facility Address: Date: <br /> FLYING J TRAVEL PLAZA#618` 1501 N JACK TONE RD, RIPON May 08, 2019 <br /> R, F VIOk., T <br /> (CI .SS I,C SS Il,or MINOR NQUceto Gomp(r # , : <br /> Item# Remarks <br /> 209 CCR 2716(a-e)Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to document the following: <br /> On the 10/19/18, 11/15/18, 12/13/18, 1/10/19, 2/7/19, 3/7/19, and 4/4/19 designated operator(DO)inspection <br /> report under <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A or N from section VII through XI. <br /> On the 5/2/19 designated operator(DO)inspection report under <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A or N from section VII through XI. <br /> -Section IX <br /> The DO failed to check if the under-dispenser containment free of damage,water, debris, and hazardous substance. <br /> The DO failed to mark Yes, No, or N/A to the question"Are all sensors in under-dispenser containment located to <br /> detect a leak at the earliest opportunity?" <br /> Furthermore the designated operator failed to check if 1-2-Diesel STP 2 fuel alarm on 4/30/19 was responded to <br /> appropriately. <br /> During the designated operator inspection,the designated operator shall review the alarm history for the previous <br /> month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br /> history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br /> performing inspections at least once every 30 days at this facility and are including all of the required information on <br /> the reports. <br /> This is a repeat violation, Class II. <br /> 306 CCR 2630(d)Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The Diesel(tank#1)STP sump sensor was on top of the rib of the saddle of the tank which is approximately 2-3 <br /> inches off the lowest point of the sump. The 91 product (tank#5) STP sump sensor was 4-3 inches off the lowest <br /> point of the sump, the sensor was not raised but closer to the top of the tank saddle. Furthermore UDC 20/21 sump <br /> sensor was on top an electrical piping found in the UDC. The electrical pipe was 2-3 inches from the lowest point of <br /> the UDC.The sensors listed above were not located to detect a leak at the earliest opportunity. Monitoring <br /> equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The sensors were <br /> relocated to the lowest point of the sump by the service technician. Ensure that all monitoring equipment is <br /> maintained to detect a leak at the earliest opportunity. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> FA0006672 PR0505264 SC001 05/08/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 6 of 8 Underground Storage Tank Program OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />