Laserfiche WebLink
DATE 11/16/2017 <br /> ,TIME ,', 01:00 pm-03:00 pm <br /> DURATION 12h <br /> TECH{S) ''. T.Weiser <br /> )ONES COVEY 4ROUR, INC. ;roe# 9016214 <br /> 9595 Lucas Ranch Road Suite 100 P0# 1953491 <br /> Rancho Cucamonga,California 91730 <br /> (888)972-7581 PAYMENT ' Direct Bill, NET 45 <br /> info@JonesCovey.com <br /> OUST©MERE L <br /> . t SERVICE <br /> Pilot Flying J 618 Ripon <br /> Thank you for allowing Jones Covey Group, Inc.to be your 1501 N.Jack Tone Road <br /> service partner! { Ripon, CA 95366 <br /> L 7 ANNULAR DIESEL 1 ANN HIGH LIQUID ALARM ALARM NOV 16, 2017 16:43 <br /> L 7 ANNULAR DIESEL 1 ANN HIGH LIQUID ALARM CLEAR NOV 16,2017 16:22 <br /> L 7 ANNULAR DIESEL 1 ANN HIGH LIQUID ALARM ALARM NOV 16, 2017 16:06 <br /> L 7 ANNULAR DIESEL 1 ANN HIGH LIQUID ALARM CLEAR NOV 16,2017 15:57 <br /> L 7 ANNULAR DIESEL 1 ANN HIGH LIQUID ALARM ALARM NOV 16, 2017 15:52 <br /> L 7 ANNULAR DIESEL 1 ANN LOW LIQUID ALARM CLEAR NOV 16,2017 15:20 <br /> L 7 ANNULAR DIESEL 1 ANN LOW LIQUID ALARM ALARM NOV 16, 2017 15:19 <br /> L 7 ANNULAR DIESEL 1 ANN HIGH LIQUID ALARM CLEAR NOV 16,2017 15:19 <br /> L 7 ANNULAR DIESEL 1 ANN HIGH LIQUID ALARM ALARM NOV 16, 2017 13:56 <br /> L 7 ANNULAR DIESEL 1 ANN HIGH LIQUID ALARM CLEAR NOV 16,2017 13:43 <br /> L 7 ANNULAR DIESEL 1 ANN HIGH LIQUID ALARM ALARM NOV 16, 2017 13:40 <br /> JOB DETAILS ~Please get the pump serial numbers when working on the dispensers to verify the warranty- <br /> 11/16 Arrived onsite and found L7 in alarm. Sensor is good, but I re spliced the wire connection at <br /> the sensor.Still in alarm, metered out the wires going from TLS to the sensor, all are ok(around <br /> 98K ohms.)Readings on the TLS show 28K ohms, this shows me the V/R sensor module is bad in the V/R <br /> panel.Will return to replace. No shut downs are programmed for this sensor. <br /> 11/21 Returned with a new sensor module, no help(reinstalled original module.) Installed sensor <br /> directly to TLS,all test ok. Further trouble shooting led to another wire connection in Jbox. <br /> Respliced that connection and was able to obtain normal readings on sensor. Reconnected wires in TLS <br /> and All Functions Normal at departure. During time of wire repair, (3) L29 alarms were automatically <br /> triggered and self-cleared with no release. <br /> Description Qty Rate Total <br /> Trave -Pilot 4.50 55.00 247.50 <br /> i Travel <br /> Labor_ 2.00 $75.00 _ $150.00 <br /> Labor Charges <br /> Travel Pilot 4.50 $55.00 $247.50 <br /> Travel <br /> Labor 2.50 $75.00 $187.50 <br /> Labor Charges <br /> MILEAGE 588.00 $0.40 $235.20 <br /> i <br />