My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018-2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2018-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 9:05:40 AM
Creation date
6/23/2020 6:57:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018-2019
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2018-2019.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
256
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> S A N 3J O A Q O IN Environmental Health Department <br /> C O u N T Y-�----- <br /> U dergl®unQr €ge alk Pr�sg <br /> Facility Name: Facility Address: Date: <br /> FLYING J TRAVEL PLAZA#618* 1501 N JACK TONE RD, RIPON May 08, 2019 <br /> t Cs 4F�' 5y t,.A ^2.''s 2A 't`' i #y - Y' :' <br /> ~ a (Ct IkSS l O SS II ar WIINOR o <br /> Inv <br /> > <br /> w <br /> Item# Remarks <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the Diesel(tank#1)STP sump,and oil/water separator(tank#7)sump. If water could enter <br /> into the secondary containment by precipitation or infiltration, it must be removed and disposed of properly. The <br /> service technician removed the liquid from the Diesel(tank#1)and oil/water separator(tank#7)sump. Ensure that <br /> all sumps and annular spaces are maintained free of liquid. <br /> This was corrected on site. <br /> This is a repeat violation, Class Il. <br /> 316 HSC 25290.1(c3), 25290.2(c3)Secondary containment not constructed to prevent water intrusion(after Jul 2003). <br /> Water was found in the Biodiesel(tank#8)fill, STP and Vent sumps. Secondary containment shall be constructed to <br /> prevent any water intrusion into the system by precipitation, infiltration,or surface runoff. Immediately remove this <br /> liquid, make a hazardous waste determination per Title 22 hazardous waste regulations, and manage accordingly. <br /> Immediately contact a properly licensed,trained, and certified contractor to address the water intrusion into the <br /> Biodiesel(tank#8)fill, STP and Vent sumps under permit and inspection of the EHD, if required. <br /> This is a repeat violation, Class II. <br /> 320 CCR 2635, 2637.2,2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Owners or operators of underground storage tanks that do not meet California Code of regulations,title 23 division <br /> 3, chapter 16 section 2635(c)(2)shall test overfill prevention equipment once by October 13th,2018 and every 36 <br /> months thereafter; and within 30 days of the date of a repair.The site conducted the test on Diesel product(tank#1) <br /> Diesel product(tank#2), Diesel product(tank#3), 87 product(tank#4), 91 product(tank#5), Diesel(tank#6)and <br /> Biodiesel product(tank#8)on 12/13/18, over two months late. Ensure to conduct overfill prevention equipment <br /> inspection within the time frame provided by the regulation and submit test results within 30 days of performing the <br /> inspection. Ensure a 48 hour notification is provided to EHD prior to conducting the inspection.Take all necessary <br /> precautions to ensure testing is performed in a timely manner. <br /> Oil water separator(Tank#7) In the tank forms under overfill protection, it states"audible and visual'as the means <br /> of overfill however based on the installation date of the tank(1994)"audible and visual'cannot be used as the only <br /> means of overfill. For a regulated new UST, an"Audible and visual'overfill can be used with Ball floats, or with <br /> double wall vent line,and double wall riser pipe. Ensure the correct overfill protection is used and listed for the oil <br /> water separator(tank#7) <br /> Furthermore, overfill prevention equipment inspection for the oil/water separator(tank#7)has not been performed <br /> and it was due by October 13th, 2018. Take all necessary precautions to ensure testing is performed in a timely <br /> manner. Immediately schedule this test and provide 48 hours notification to the EHD. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> FA0006672 PR0505264 SCO01 05/08/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 7 of S Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.