My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BANNER
>
6437
>
2300 - Underground Storage Tank Program
>
PR0506004
>
COMPLIANCE INFO_2008-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2024 4:07:28 PM
Creation date
6/23/2020 6:57:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2009
RECORD_ID
PR0506004
PE
2361
FACILITY_ID
FA0007140
FACILITY_NAME
FLAG CITY SHELL*
STREET_NUMBER
6437
Direction
W
STREET_NAME
BANNER
STREET_TYPE
ST
City
LODI
Zip
95242
APN
05532019
CURRENT_STATUS
01
SITE_LOCATION
6437 W BANNER ST
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506004_6437 W BANNER_2008-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
336
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S Bravo Systems, Inc. Page 1 of 2 <br /> Issue Date: March 5,2002 <br /> Revision Date:November 25,2003 <br /> S Bravo Systems, Inc. <br /> Model B-2000 Shallow Steel Dispenser Containment System <br /> Model B-8600 Aboveground/Marina Steel Dispenser Containment System <br /> INTERSTITIAL DETECTOR(LIQUID-PHASE) <br /> Detector: <br /> Output type: qualitative, non-discriminating <br /> Sampling frequency: continuous <br /> Operating principle: float switch <br /> Test Results: <br /> unleaded gasoline diesel water <br /> Detection time (hrs) 0.52 0.48 1.43 <br /> Fall time (sec) <br /> Lower detection limit(ml) 197.39 181.08 542.10 <br /> (6.7 ounces) (6.12 ounces) (18.3 ounces) <br /> *The fall time was not determined. Evaluator notes that fall time is irrelevant because the only way to reset the <br /> system is to remove the liquid from the float sump and manually reset the shear valve. <br /> Specificity Results: <br /> Responds to any liquid in sufficient quantities to raise the float which trips the shear valve. No additional materials <br /> tested. <br /> Manufacturer's Specifications: <br /> The Model B-2000 and Model B-8600 systems use a float coupled to the shear valve mechanism of the dispenser. <br /> When any liquid (water or fuel) enters the sump in sufficient amounts to raise the float, the shear valve is tripped, <br /> preventing dispensing of fuel from that particular dispenser. The systems are designed with baffles that initially <br /> restrict the tripping to the dispenser in question. If sufficient liquid enters the section, it will overflow the baffle <br /> and trip the shear valves on the adjacent product inlet within the dispenser pan. <br /> S Bravo Systems, Inc. Evaluator: Ken Wilcox Associates <br /> 2929 Vail Avenue Tel: (816) 443-2494 <br /> Commerce, CA 90040 Dates of Evaluation: 01/27/02, 11/05/03 <br /> Tel: (714) 888-4133 <br /> E-mail: info@sbravo.com <br /> URL: www.sbravo.com <br /> Home I Vendors: A - F Vendors: G - M Vendors: N -S I Vendors: T- Z I Method Index <br /> http://www.nwglde.org/evals/s_bravo_systems_a.html 5/27/2008 <br />
The URL can be used to link to this page
Your browser does not support the video tag.