My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BANNER
>
6437
>
2300 - Underground Storage Tank Program
>
PR0506004
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2024 4:20:39 PM
Creation date
6/23/2020 6:57:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0506004
PE
2361
FACILITY_ID
FA0007140
FACILITY_NAME
FLAG CITY SHELL*
STREET_NUMBER
6437
Direction
W
STREET_NAME
BANNER
STREET_TYPE
ST
City
LODI
Zip
95242
APN
05532019
CURRENT_STATUS
01
SITE_LOCATION
6437 W BANNER ST
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506004_6437 W BANNER_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
426
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, e <br />SWy <br />RCB Januar 2002 Page Z— of <br />A 'T A 1`TV A IUWTTT AD TTi CTTNf_' <br />Test Method Developed By: X Tank Manufacturer ❑ Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure X Vacuum ❑ Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Gast Vacuum Pump/Vacuum Gauges in Hg. <br />MENEM <br />Tank # 1 Tank # 2&3 <br />Equipment Resolution: -1/2-301-1g. — <br />y <br />Tank # Tank # <br />Is Tank Exempt From Testing?' <br />❑ Yes x No <br />❑ Yes x No <br />❑ Yes No <br />❑ Yes ❑ No <br />Tank Capacity: <br />20K <br />20K Split 10/10 <br />Tank Material: <br />Glass/Steel <br />Glass/Steel <br />Tank Manufacturer: <br />Trusco <br />Trusco <br />Product Stored: <br />Regular 87 <br />Supreme 91/Diesel <br />_ <br />Wait time between applying <br />vacuum and starting test: <br />1 Hour <br />1 Hour <br />-- <br />Test Start Time: <br />9:35 <br />9:25 <br />Initial Reading (Rj): <br />-10 Hg. <br />-10 Hg. <br />Test End Time: <br />11:35 <br />11:25 <br />Final Reading (RF): <br />-10 Hg. <br />-10 Hg. <br />Test Duration: <br />2 Hours <br />2 Hours <br />Change in Reading (RF -RT): <br />OHg. <br />0 Hg. <br />—i <br />Pass/Fail Threshold or Criteria: <br />No loss in Hg. <br />No loss in Hg. <br />Test Result: <br />I XPass ❑ Fail <br />X Pass ❑ Fai <br />Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />NA <br />❑ Yes ❑ No DNA— <br />Was sensor properly replaced and <br />Was <br />verified functional after testin ? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />❑ Yes ❑ No [INA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant' vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.