Laserfiche WebLink
SWRCB, January 2006 <br />Spill Bucket Testing Report Form <br />This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br />printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br />1 FArTr:TTV TNFnRMATTnN <br />Facility Name: FLAG CITY SHELL Date of JEEP 5ZTN71-1 <br />Facility Address: 6437 W BANNER RD LODI CA 95240 °`" ''`` <br />Facility Contact: Rupi Padda Phone: <br />Date Local Agency Was Notified of Testing: 2-24-17 <br />Name of Local Agency Inspector (if present during testing): <br />DIY N Pg as . --- <br />2. TESTING CONTRACTOR INFORMATION DEPARTMIN I <br />Company Name: AFFORDA TEST 416 211 Street Galt, CA 95632 (209) 744-0112 Fax: (209) 744-0116 <br />Technician Conducting Test: ❑ Ed Stearns ❑ Zane A. Nimmo ® David A. Winkler ❑ Felix G. Ramirez <br />8184188 5263322 -UT 5263373 -UT 5273934 -UT <br />II Credentials': ® ICC Service Tech. ® SWRCB Tank Tester (I <br />3 CPIi.1, RITC'KF.T TFCTING TNFnRMATION <br />Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other <br />Test Equipment Used: H2O & <br />TAPE MEASURE <br />Equipment Resolution: 1/16 <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc.) <br />1 87 <br />2 91 <br />3 DSL <br />4 <br />Bucket Installation Type: <br />® Direct Bury <br />El Contained in Sump <br />®Direct Bury <br />❑Contained in Sump <br />®Direct Bury <br />El Contained in <br />Sump <br />E] Direct Bury <br />El Contained in <br />Sum <br />Bucket Diameter: <br />11 <br />11 <br />11 <br />Bucket Depth: <br />12.50 <br />12.50 <br />12.50 <br />Wait time between applying <br />vacuum/water and start of test: <br />NA <br />NA <br />NA <br />NA <br />Test Start Time (Ti): <br />9 <br />9 <br />9 <br />Initial Reading (Ri): <br />12 <br />12 <br />12 <br />Test End Time (TF): <br />10 <br />10 <br />10 <br />Final Reading (RF): <br />12 <br />12 <br />12 <br />Test Duration (TF — TI): <br />1 HR <br />1 HR <br />1 HR <br />Change in Reading (RF - Ri): <br />0 <br />0 <br />O <br />Pass/Fail Threshold or <br />Criteria: <br />1/16 <br />1/16 <br />1/16 <br />Test Result: <br />® Pass ❑ <br />Fail <br />Pass <br />❑ <br />Fail <br />0 Pass ' ❑ Fail <br />❑ Pass ❑ <br />)Fail <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />®pw <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: <br />Date: 3-27-17 <br />' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />