My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2003-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 1:15:55 PM
Creation date
6/23/2020 6:57:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2005
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2003-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
442
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IrARCO Products Company <br />Station # 6347 <br />Electronic Leak Detector Test Data Sheet <br />Date &,,5 20 ©3 <br />Address 2430 Joe Pombo Parkway,Tracy <br />Test Information <br />Comments: <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct. The mechanical leak detector test pass/fail is determined using a low flow <br />threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor TAIT ENVIRONMENTAL SYSTEMS <br />Technician O"t-ai'n. Lic# <br />Signature <br />Revision 5101 <br />1 <br />2 <br />3 <br />4 <br />S <br />Product <br />7 <br />Manufacturer <br />.-- <br />te -:s <br />Model <br />.�- <br />Line Bleed Back (ml) <br />�.-- <br />Check Valve Holding Pressure <br />(psi) <br />Test Leak Rate (ml/min) (gph) <br />/ Cl <br />1 �� <br />PASS or FAIL <br />Comments: <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct. The mechanical leak detector test pass/fail is determined using a low flow <br />threshold trip rate of 3 gph at 10 PSI. <br />Inspected By: Contractor TAIT ENVIRONMENTAL SYSTEMS <br />Technician O"t-ai'n. Lic# <br />Signature <br />Revision 5101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.