My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 2:56:37 PM
Creation date
6/23/2020 6:57:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
377
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONIT NG SYSTEM CERTIFICWION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code REGRIVE-"o <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be r ar d for each <br /> monitoring_system control panel by the technician who performs the work. A copy of this form must be provided to the tank system'o r/ p <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date <br /> 1 h1A.AEtV �iL <br /> A. General Information PES IT/SE l <br /> caS <br /> Facility Name: ARCO AM PM Bldg.No.: <br /> Site Address: 2430 Joe Pombo Parkway City: Tracy Zip: 95377 <br /> Facility Contact Person: Ranjeet Singh Contact Phone No.: (209) 830-8778 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 10/27/2011 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicates ecific a ui ment inspected/serviced: <br /> Tank ID: T1: 87 Master Tank ID: T2: Syphon <br /> ®In-Tank Gauging Probe. Model: 109 Z In-Tank Gauging Probe. Model: 109 <br /> ®Annular Space or Vault Sensor. Model: 409 E Annular Space or Vault Sensor. Model: 409 1,>. <br /> Z Piping Sump/Trench Sensor(s). Model: 323 ®Piping Sump/Trench Sensor(s). Model: 323 <br /> ,r <br /> Z Fill Sump Sensor(s). Model: 323 ®Fill Sump Sensor(s). Model: 323 <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: HE qLrH <br /> ®Electronic Line Leak Detector. Model: 8484 ❑Electronic Line Leak Detector. Model: ITS R <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: T3: Premium Tank ID: <br /> Z In-Tank Gauging Probe. Model: 109 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 409 ❑Annular Space or Vault Sensor. Model: <br /> Z Piping Sump/Trench Sensor(s). Model: 323 ❑Piping Sump/Trench Sensor(s). Model: <br /> Z Fill Sump Sensor(s). Model: 323 E]Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> Z Electronic Line Leak Detector. Model: 8484 ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1/2 Dispenser ID: 3/4 <br /> Z Dispenser Containment Sensor(s). Model: 323 Z Dispenser Containment Sensor(s). Model: 323 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> Z Dispense'Containment Sensor(s). Model: 323 Z Dispenser Containment Sensor(s). Model: 323 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9110 Dispenser ID: 11112 <br /> Z Dispenser Containment Sensor(s). Model: 323 Z Dispenser Containment Sensor(s). Model: 323 <br /> Z Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): Z System set-up Z Alarm history report <br /> Technician Name(print): Guadalupe Sanchez Signature: <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: Reliable Petroleum Services Inc. Rhone No.: 209 845-8586 <br /> Testing Company Address: 11930 Horseshoe Road, Oakdale CA 95361 Date of Testing/Servicing: 10/27/2011 <br /> Page 1 of 3 <br /> Rev(2/08) <br />
The URL can be used to link to this page
Your browser does not support the video tag.