My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 3:10:02 PM
Creation date
6/23/2020 6:57:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2013-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
193
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN4JOAQUIN Environmental Health Department <br />COUNTY— <br />to <br />Facility Name: <br />Facility Address: <br />Date: <br />ARCO AM PM #82602* <br />2430 JOE POMBO PKWY, TRACY <br />October 17, 2018 <br />Item # <br />Remarks <br />103 <br />HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br />Financial responsibility documents have not been submitted to the EHD. Current financial responsibility documents <br />uploaded to CERS were last signed on 6/5/17 and are required to be submitted annually. The owner of the site <br />Ranjeet Singh logged into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and <br />uploaded the required documents while the inspector was on site. <br />This was corrected on site. <br />This is a repeat violation, Class 11. <br />307 <br />CCR 2631 (g), 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br />The 91 product and 87 product siphon split tank annular sensor failed to come out of audible and visual alarm when <br />tested and, therefore, the tank is not monitored. The interstitial space shall be monitored with a monitoring system <br />connected to an audible and visual alarm system. The sensor was replaced and retested during the inspection. A <br />"UST Retrofit Verification with Inspector Already Onsite" form has been completed and provided to the operator and <br />This was corrected on site. <br />This is a repeat violation, Class 11. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by November 16th, 2018. <br />Document reviewed: Monitoring system certification test results from 2015, 2016, 2017, secondary containment <br />testing from 2017, employee training, response plan, maintenance records, monitoring plan, financial <br />responsibility documents and designated operator monthly inspection reports from October 2017- September <br />2018. <br />Starting September 1, 2018, all in -office CERS help will be provided at EHD hourly rate ($152). To schedule an <br />appointment, please call (209) 468-3420. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: October 17, 2018 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title: <br />ZUNA BARKER, EH Specialist <br />(209) 953-7311 <br />Jazwinder Sanghera, Cashier with permission from VP <br />FA0007634 PRO506796SC001 10/17/2018 <br />e*o23*1 Rev. 09/28/2018 Page *m* Underground Storage Tank Program mn <br />1808E.Hazelton Avenue | Stockton, California Q52U51 T 209488-34201 F 209 464-0138 1 vmww.sjmehd.00m <br />
The URL can be used to link to this page
Your browser does not support the video tag.