Laserfiche WebLink
ED <br />MONITORING SYSTEM CERTIFICA V <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited. Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California C \pf f �ns <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided tot tg*VTA F_P <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 d <br />A. General Information <br />KarAIMUMM <br />Facility Name: Arco # 82602 Bldg. No.: <br />Site Address: _2430 Joe Pombo Pkwy City: Tracy, CA Zip: 95376 <br />Facility Contact Person: Vikram Contact Phone No.: (209) 579-4014 <br />Make/Model of Monitoring System: Veeder Root TLS -350 Date of Testing/Servicing: 10/1912017 <br />B. Inventory of Equipment Tested/Certified <br />/`hn.d, thn ann—viote h— to inA;"ta enaeifin Pnnin,nnnt inenPPtPd/cenriPPde <br />Tank ID: T1: 87 Master <br />Tank ID: T2: 87 Syphon <br />® In -Tank Gauging Probe. <br />Model: 847390-109 <br />® In -Tank Gauging Probe. <br />Model: 847390-109 <br />® Annular Space or Vault Sensor. <br />Model: 794390409 <br />® Annular Space or Vault Sensor. <br />Model: 794390.409(split tank) <br />® Piping Sump / Trench Sensor(s). <br />Model: 794380-323 <br />® Piping Sump / Trench Sensor(s). <br />Model: 794380-208 <br />® Fill Sump Sensor(s). <br />Model: 794380-208 <br />® Fill Sump Sensor(s). <br />Model: 794380-323 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: 8484 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: T3: 91 <br />Tank ID: <br />® In -Tank Gauging Probe. <br />Model: 847390-109 <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: 7943904309(split tank) <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: 794380-323 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />® Fill Sump Sensor(s). <br />Model: 794380-323 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: 8484 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1&2 <br />Dispenser ID: 3&4 <br />® Dispenser Containment Sensor(s). <br />Model: 794380-323 <br />® Dispenser Containment Sensor(s). <br />Model: 794380-323 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 6&6 <br />Dispenser ID: 7&8 <br />® Dispenser Containment Sensor(s). <br />Model: 794380-323 <br />® Dispenser Containment Sensor(s). <br />Model: 794380-323 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9&10 <br />Dispenser ID: 11&12 <br />® Dispenser Containment Sensor(s). <br />Model: 794380-323 <br />® Dispenser Containment Sensor(s). <br />Model: 794380-323 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the Facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): Guadalupe Sanchez <br />Certification No.: A30138 <br />Signatu� er'" <br />License. No.: 1005444 <br />Testing Company Name: Diamond Petroleum Services, Inc. Phone No.: (925) 470-0803 <br />Testing Company Address: 3619 King Ct. Antioch, CA. 94509 Date of Testing/Servicing: 10/19/2017 <br />Page 1 of 4 <br />Rev (2/08) <br />