My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2360
>
2300 - Underground Storage Tank Program
>
PR0507204
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/29/2024 11:25:26 AM
Creation date
6/23/2020 6:58:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0507204
PE
2361
FACILITY_ID
FA0007735
FACILITY_NAME
7-ELEVEN INC #32262
STREET_NUMBER
2360
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23819001
CURRENT_STATUS
01
SITE_LOCATION
2360 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507204_2360 W GRANT LINE_2009-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />a <br />8501 N MOPAC EXPRESSWAY, SUITE 400 <br />TEST DATE: 04/20/10 <br />AUSTIN, TEXAS 78759 (512) 451-6334 WORK ORDER NUMBER: 2273787 <br />CLIENT: 7-ELEVEN, INC. <br />SITE: 7-ELEVEN #32262, <br />MKT 2368 <br />Tank manifolded: No Bottom to top fill in inches: <br />92.0 <br />Tank ID: PUL 6 <br />Product: PREMIUM <br />Vent manifolded: YES Bottom to grade in inches: <br />Capacity in gallons: 9,684 <br />Vapor recovery manifolded: YES Fill pipe length in inches: <br />Diameter in inches: 89.00 <br />Overfill protection: YES Fill pipe diameter in inches: <br />Length in inches: 341 <br />Overspill protection: YES Stage I vapor recovery: <br />DUAL <br />Material: DW FIBERG <br />Installed: ATG Stage II vapor recovery: <br />ASSIST <br />CP installed on: <br />COMMENTS <br />New/passed Failed/replaced New/passed <br />Failed/replaced <br />PSI at tank bottom: <br />Fluid level in inches: <br />L.D. #1 L.D. #1 L.D. #2 <br />L.D. #2 <br />UFT/OFT: <br />Make: VAPORLESS <br />Fluid volume in gallons: <br />Model: LD2000 <br />Tank water level in inches: <br />S/N: 07071145 <br />Test time: <br />NOT <br />Open time in sec: 1.90 <br />Number of thermisters: <br />TESTED <br />Holding psi: 31 <br />NOT <br />Specific gravity: <br />Resiliency cc: 250 TESTED <br />Water table depth in inches: <br />Test leak rate ml/m: 189.0 <br />Determined by (method): <br />Metering psi: 19 <br />Leak rate in gph: <br />Calib. leak in gph: 3.00 <br />Result: <br />Results: PASS <br />COMMENTS <br />COMMENTS <br />Material: DW FLEX <br />Test time: <br />Ullage volume: <br />Diameter (in): 2.0 <br />Ullage pressure: <br />Length (ft): 260.0 <br />Results: <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />DATA FOR UTS-4T ONLY: <br />Test 1: Start time: <br />Time of test 1: <br />Finish psi: NOT NOT NOT <br />NOT <br />Temperature: <br />NOT <br />Vol change cc: TESTED TESTED TESTED <br />Test 2: Start time: <br />TESTED <br />Flow rate (cfh): <br />TESTED <br />Finish psi: <br />Time of test 2: <br />Vol change cc: <br />Test 3: Start time: <br />Temperature: <br />Finish psi: <br />Flow rate (cfh): <br />Vol change cc: <br />Time of test 3: <br />Final gph: <br />Temperature: <br />Result: <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />COMMENTS <br />Pump make: FE PETRO <br />COMMENTS Impact Valves Operational: YES <br />Printed 04/28/2010 08:53 ACRAMER <br />
The URL can be used to link to this page
Your browser does not support the video tag.