Laserfiche WebLink
.A'onlilnled,ti-rota Perk I <br /> For the purposes of this review,I have; <br /> 1 ) Reviewed the construction and installation procedures for the single wall (Retrofit-S) and <br /> double wall(Retrofit-SD-AB)F-Series Retrofit Split Fiberglass fittings for conduit. <br /> ?) Reviewed the construction and installation procedures for the single wall (Retrofit-S) and <br /> double Nvall (Retrofit-SD-AB) F-Series Retrofit Split Fiberglass fittings for fiberglass pipe. <br /> 'i)Reviewed add-on parts that are used to increase the angle of entry.These wedges are made <br /> from the sank- material as the fittings and provide incremental degrees of additional angle. <br /> 4) Reviewed materials used to construct the secondary containment system for sufficient <br /> thickness,density and corrosion resistance to Prevent structural weakening or damage to <br /> the secondary containment systeiii as a result of contact with hazardous substances <br /> contained in common fuels. <br /> Upon review of the manufacturing procedures, the employment of the materials used in the Bravo <br /> Systems F-Scrics Retrofit-S and Rctrofit-SD-AB product lines and the manufacturer's installation <br /> guidelines.it is my conclusion that sound design and engineering ol'this product for use with fiberglass <br /> single wall and double walled containment structures and al-orementioned pipe types Nvill meet or <br /> exceed the secondary containment requirements for corrosion resistance and material compatibility <br /> ofall motor vehicle fuels, alternative fuels or their additives currently used by petroleum marketers <br /> today. I approve the above engineering specifications for the following Bravo F-Series fittings: <br /> IF-Series SingleAVall Fiberglass Split Retrofit Fittings for fiat sump walls: <br /> For Conduit: F-05-Retrofit-S, F-07-Retrofit-S, F-1 O-Retrofit-S <br /> For Pipe: F-20-Retrofit-S.F-30-Retrofit-S, F-40-Retrofit-S. F-60-Retrofit-S <br /> For LCX Pipe: F-20-Retrofit-S-LCX- F-30-Retrofit-S-LCX, F-40-Retrofit-S-LCX <br /> F-Series SingleWall Fiberglass Split Retrofit Fittings for round sump walls: <br /> For Conduit: F-05-Retrofit-S-RND,F-07-Retrofit S-RND.F-10-Retrofit-S-RNID <br /> For Pipe: F-20-Retrofit-S-RND. F-30-Retrofit-S-11ND,F-40-Retrofit-S-RND,F-60-Retrofit-S-RND <br /> For LCX Pipe: F-20-Retrofit-S-RND-L.CX,F-30-Retrofit-S-RND-LCX.F-40-Retrofit-S-RND-LCX <br /> F-Series DoubleWall (Double-Sided) Fiberglass Split Retrofit Fittings for flat sump walls: <br /> .For Conduit: F-05-Retrofit-SD-AB.F-07-Retrofit-SD-AB,F-10-Retrofit-SD-AB <br /> For Pipe: F-20-Retrofit-SD-AB.F-30-Retrofit-SD-AB, F-40Retrofit-SD-AB, F-60-Retrofit-SD-AB <br /> For LCX Pipe: F-20-Retrofit-SD-AB-LCX. F-30-Retrofit-SD-AB-LCX, F-40-Re1rofit-SD-AB-LCX <br /> F-Series Double all(Double-Sided) Fiberglass Split.Retrofit Fittings for round sump walls: <br /> Por Conduit: F-05-Retrofit-SD-AB-RND, F-07-Retrofit-SD-AB-RND,F-10-Retrofit-SD-AB-RND <br /> For Pipe: F-20-Retrofit-SD-AB-RND,1-30-Retrofit-SD-AB-RND, F-40-Retrofit-SD-A'B-11ND, <br /> F-60-Retrofit-SD-A13-RND <br /> For LCX Pipe: F-20-Retrofit-SD-AB-RND-LCX, F-30-Retrofit-SD-Al3-RND-LCX, <br /> F-40-Retrofit-SD-AB-RND-LCX <br /> Please contact tt1e with any questions at 323-898-4136. <br /> Si erely, <br /> n~r 0 30 77 TH <br /> .Don K.�%Aai , <br /> Mechanical Engineer d CCA , <br /> OFCA4w' <br /> 3RP-FS-RETROFIT-S PAGE 2 of 2 <br />