My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_2007-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 9:01:09 AM
Creation date
6/23/2020 6:58:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2013
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_2007-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
560
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 7 of <br /> 6. PIPING SUMT TESTING <br /> Test Method Developed.By: ❑Sump Manufacturer aIndustry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum &Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used:ELLDS 1s51 Equipment Resolution: .0007 <br /> Sump# ' Sump# r / Sump# Sump# <br /> Sump Diameter: , ' <br /> Sump Depth: <br /> Sump Material: <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: �y <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: _z <br /> Condition of sump prior to testing: Clkl <br /> Portion of Sump Tested' 2"above highest 2"above highest 2"above highest 2"above highest <br /> penetration penetration penetration penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No Q"NA ❑Yes ❑No ❑ TA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> product and water)?* <br /> Turbine shutdown response time N/A NIA N/A N/A <br /> Is system programmed for fail-safe ❑Yes ❑No Cl/NA ❑Yes ❑No OVA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> shutdown? <br /> Was fail-safe verified to be ❑Yes ❑No O NA ❑Yes ❑No ff ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 30 minutes 30 minutes 30 minutes 30 minutes <br /> test: <br /> Test Start Time: 2 a v k <br /> Initial Reading(RI): / ;. y 5;1.f- 6 <br /> Test End Time: 12 !17 <br /> Final Reading(RF): 957 Y Z7 95"1_7 <br /> Test Duration: 15 minutes 15 minutes 15 minutes 15 minutes <br /> Change in Reading(RF-R): ,v E; 7_r 5-Q <br /> Pass/Fail Threshold or Criteria: 0.0020 0.0020 0.0020 0.0020 <br /> Test Result: 9,Pass ❑Fail K Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? R'Yes ❑No ❑NA 3°Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and Comes ❑No ❑NA s ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Chevron#20-8117 <br /> 755 S.Tracy Blvd. <br /> Tracy,Ca 95376 <br /> If the entire depth of the sump is not SP 989 Nick Harvey wer to a�of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the enth #N11087 <br />