My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_2007-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 9:01:09 AM
Creation date
6/23/2020 6:58:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2013
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_2007-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
560
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page / of <br /> 8. A RISER CONTAINMENT STESOG <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer -RIndustry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used:ELLDS Equipment Resolution: .0007 <br /> Fill Sump# q- -7 Fill Sump# Till Sump# Fill Sump# <br /> Sump Diameter: <br /> Sump Depth: <br /> Height from Tank Top to Top of 13 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 3 r t <br /> Electrical Penetration: <br /> Condition of sump prior to , <br /> testing: <br /> Portion of Sump Tested 1 2"above highest 2"above highest 2"above highest 2"above highest <br /> penetration penetration penetration penetration <br /> Sump Material: <br /> Wait time between applying `' <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 'Z <br /> Initial Reading(RI): l . :3 C- 1• 0.3 ,3 <br /> Test End Time: G':5-6, 10! '5-7 <br /> Final Reading(RF): 1, 41.3 f. 0 <br /> Test Duration: 15 minutes 15 minutes 15 minutes 15 minutes <br /> Change in Reading(RF-RI): c>c3 7.3 0-- s�7 <br /> Pass/Fail Threshold or Criteria: 0.0020 0.0020 0.0020 0.0020 <br /> Test Result: I&Pass ❑Fail I.Pass ❑Fail 0 Pass ❑Fail ❑ Pass ❑Fail <br /> Is there a sensor in the sump? 'EWes ❑No Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes ❑No 0 NA ❑Yes ❑No IIIA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? Yes ❑No ❑NA I(Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and i Yes ❑No ❑NA Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Chevron#20-5117 <br /> 755 S.Tracy Blvd. <br /> Tracy,Ca 95376 <br /> SB 989 Nick Harvey <br /> #N11087 <br />
The URL can be used to link to this page
Your browser does not support the video tag.