Laserfiche WebLink
I <br /> 1�" 'e�✓ San Joaquin County <br /> APR 0 6 2016 Environmental Health Department JUN 2 3 2016 <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjaov.oro/ehd 1""'t <br /> Underground Storage Tank Pro gram<Inspecton Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON#208117** 755 S TRACY BLVD TRACY March 04 2016 <br /> UST System Observatldns <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump r-COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed V -)R COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi LV R COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty V R COS <br /> 325 CCR 2635(b) Spill_container failed to_contain a minimum capacity of five gallons <br /> _ V � R COS <br /> �m <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill_. requirements r . <br /> �- ___ _ _ __ _�_ -V R COS <br /> ----- — <br /> 27 CCR 2635(b){2} Overfill prevention was overridden V R : COS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status V R r COS <br /> 329 CCR 2717.1(8) Tampered with red tag :R r COS <br /> �V <br /> 330 CCR 2717.1(f) Deposited petroleum into a red tagged UST V R � COS <br /> 1 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms V R --COS <br /> 332 CCR 2631.1 UST system not compatible with the substance stored V R DCOS <br /> 333 MSC 25298(b) Failed to comply with temporary closure requirements V R r COS <br /> 4 HSC 25298(c) Failed to comply with permanent closure requirements V _ R COS <br /> Non-Pressurized,P'Iping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve i V c R COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed CV r;R COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) <br /> c V R COS <br /> 4 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ^V m:R COS <br /> ®thee Violations.., <br /> 2010 See below Unlisted Administration/Documentation violation V 4 R e1 COS <br /> 2030 See below Unlisted Operations/Maintenance violation v L L V R COS <br /> 2060 See below Unlisted Design/Construction violation V R c COS <br /> SUMMARY OF VIOLATIONS: . <br /> tcLAss I,GLASS II 6r MINOR�Notiae to comply}, <br /> . , . - . , <br /> Item# Remarks <br /> 306 CCR 2630(d)Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 87 product submersible turbine pump(STP) sump boot was clamped shut and the schreider valve was pointed up. <br /> The service technician unclamped the boot and pointed the schreider valve to a down position, correcting the problem. <br /> Going forth, assure that the boot is not clamped shut and/or the schreider valve is open and pointed down. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> On site on March 4, 2016 to complete the monitoring system certification and line leak detector testing of the 91 <br /> Page 3 of 4 <br />