My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 9:06:08 AM
Creation date
6/23/2020 6:58:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_2014-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> FEB 19 2016 <br /> Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at hfp://www.swt-i <br /> MONITORING SYSTEM CERTIFICATION UC61-r 1 r1C:06 Tlfp1zkIT <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information " <br /> Facility Name: CHEVRON#208117 Bldg.No.: <br /> Site Address: 755 S.TRACY BLVD City: TRACY Zip: 95376 <br /> Facility Contact Person: MGR-MARIA Contact Phone No.: 209-830-0370 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 2/10/2016 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific 2guipment inspected/serviced: <br /> Tank ID: T 1-PREMIUM Tank ID: T 2-REGULAR <br /> N In-Tank Gauging Probe. Model: 576013-730 Vo In-Tank Gauging Probe. Model: 576013-730 <br /> P Annular Space or Vault Sensor. Model: 794390-409 NW Annular Space or Vault Sensor. Model: 794390-409 <br /> rV Piping Sump/Trench Sensor(s). Model: 794380-352 P Piping Sump/Trench Sensor(s). Model: 794380-352 <br /> Fill Sump Sensor(s). Model: 794380-209 P Fill Sump Sensor(s). Model: 794380-209 <br /> r Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> �I Electronic Line Leak Detector. Model: Veeder Root PLLD rV Electronic Line Leak Detector. Model: Veeder Root PLLD <br /> Tank Overfill/High-Level Sensor.Model: FLAPPER d Tank Overfill/High-Level Sensor.Model: FLAPPER <br /> Other(specify equipment a and model in Section E on Pae 2). Other(specify equipment a and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: r In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: r Annular Space or Vault Sensor. Model: <br /> r Piping Sump/Trench Sensor(s). Model: r Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Pae 2). r Other(specify a ui ment tyRe and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> r7 Dispenser Containment Sensor(s).Model: 794380-208 vO Dispenser Containment Sensor(s).Model: 794380-208 <br /> W Shear Valve(s). P Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser 7/8 <br /> ID: ID: <br /> rV Dispenser Containment Sensor(s).Model: 794380-208 vO Dispenser Containment Sensor(s).Model: 794380-208 <br /> rV Shear Valve(s). rvO Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 9/i0 Dispenser 11/12 <br /> ID: ID: <br /> rvO Dispenser Containment Sensor(s).Model: 794380-208 rV Dispenser Containment Sensor(s).Model: 794380-208 <br /> rvO Shear Valve(s). V Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report;(check all that applyj:P System set- <br /> up P Alarm history report , 1— <br /> Technician Name(print): Gilbert Garcia Signature: — <br /> Certification No.: B42816 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 2/10/2016 <br /> Monitoring System Certification Page i of 3 12/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.