Laserfiche WebLink
htudvbb <br /> FEB <br /> Chevron Monitoring Certification Checklist 2016 <br /> Store Number: 208117 Address: 755 S.TRACY BLVD TRACY,CA 95376 <br /> tb1FA!TIJ RcpApTAsc:nw <br /> Date:2/10/2016 Technician: Gilbert Garcia Company:TANKNOLOGY INC. <br /> Step Instruction Tank 1-PREMIUM Tank 2-REGULAR <br /> Product PREMIUM REGULAR <br /> Tank Type <br /> (DW FRP,DW Steel,SW FRP) Fiberglass Fiberglass <br /> 1 Annular Riser Height(measured) 74.00 in. 75.00 in. <br /> 2 Tank Diameter 117.75 in. 117.75 in. <br /> For FRP tanks,1/2 circumference of the tank <br /> 3 184.87 in. 184.87 in. <br /> (see Note 1 below) <br /> Required annular sensor length: <br /> 4 FRP=Riser+1/2 Circumference=step 1+step 3 258.87 in. 259.87 in. <br /> Steel=Riser+diameter=step 1+step 1 <br /> Mark&label the required sensor length on sensor cord. <br /> 5 Label should be under the cap&serve to prevent the cord Yes Yes <br /> being pulled too short. <br /> FRP Tanks:Is the sensor installed with the marked <br /> 6 required Yes Yes <br /> length lining up with the top of the annular riser? <br /> 7 Steel Tanks:Is the sensor toughing bottom with slack <br /> above the marked required sensor length? <br /> Are the DW pipe boots"pulled back in tank sumps? <br /> 8 (YIN or N/A,note if can't be verified because clamshell Yes Yes <br /> pointing down <br /> Are tank sump sensors back in their holders and in the <br /> 9 correct position? Yes Yes <br /> (Y/N or N/A document with photo) <br /> Has the Veeder Root Battery been replaced&dated prior to failsafe? <br /> (If battery backup failed,label and leave failed battery on top of console,note in comments and advise your OM) See Comment <br /> Has Veeder Root Programming before&after testing been printed&verified? Yes <br /> (especially tank manifolding setup-see Note 2) <br /> Has Veeder Root Programming before&after been attached to the Work Order? Yes <br /> Have all sensor model numbers been verified against the Veeder Root cord label? Yes <br /> Make a note if sensor label missing or illegible,&approx.cord length for-208/-209 with missing labels <br /> Additional Comments: <br /> BATTERY TESTED 3.67 VOLTS <br /> Note 1: DW FRP Tank Circumference Note 2: Certain Veeder Root Software versions will automatically revert to the default <br /> tank manifold settings any time the programming is changed,such as when sensors are <br /> 1/2 Circum= (3.14 x tank diam) temporarily X'ed out,etc. <br /> 2 <br /> 10'diameter 1/2 Circum=188" <br /> 8'diameter 1/2 Circum=151" <br /> 6'diameter 1/2 Circum=113" <br />