Garrett Backus [EH <br />From: <br />Sent: <br />To: <br />Subject: <br />Attachments: <br />Dear Thuy: <br />Calalang, Pauline <PaulineCalalang@chevron.com> V-0-`- <br />Monday, March 10, 2014 12:00 PM <br />Thuy Tran [EH] <br />Chevron 208117-755 S Tracy Blvd. <br />91LLD retest.pdf, Inspection report3-3-14.pdf; DO-11-15-13-208117.doc; 208117 <br />RTC.pdf <br />This message is in response to the inspection report dated 3/3/2014 to Chevron Station # 208117, located at 755 <br />S Tracy Blvd., Tracy. <br />Below is our response regarding the items noted in the attached inspection report. <br />• Annual Monitoring system certification, leak detector testing and spill testing were last performed on <br />2/27/2013 and was completed on 3/3/2014, one month past due. These tests are required one every 12 <br />months. <br />o The Annual Monitoring Certification testing was three (3) days overdue from the anniversary <br />date of 2/27/13. The testing contractor originally scheduled the monitoring certification on <br />2/26/14 to this facility, however by accident, they switched the facility number with the other <br />station number when transferring the data, and that triggered the late test. Going forward, <br />Chevron will verify the schedule as well to ensure the monitoring certification is performed <br />within the timeframe. <br />• The designated operator failed to check and note the correct test dates on the November 2013 designated <br />operator monthly inspection report. The test dates section of the inspection report was left blank. <br />o The designated operator (D.0) corrected the D.O. monthly inspection report by entering the <br />correct test dates on the November 2013 D.O monthly report form. Please see attached DO <br />form. <br />• The 91 line leak detector (LLD) failed to detect a leak when tested. All line leak detectors shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. <br />o On 3/7/14, the 91 LLD passed the 3 -gallon functionality test, witnessed by inspector Thuy <br />Tran. The follow up inspection report is attached. <br />o Please see attached Return to Compliance Certification. <br />Please contact me directly if you need additional information. Thank you so much. <br />Thank you, <br />Pauline Calalang <br />UST Compliance Coordinator <br />6001 Bollinger Cyn. Rd. L 1 193 <br />San Ramon, CA. 94583 <br />Tel: 925.842.1105/Cell: 707.315.4737 <br />Fax:: 1866.420.0335 (Attn: PNCP) <br />Disclaimer: This message may contain confidential information and is intended only for the use of the parties to whom it is addressed. If you are not an intended recipient, you <br />are hereby notified that any disclosure, copying, distribution or use of any information in this message is strictly prohibited. If you have received this message in error, please <br />notify me immediately at the telephone number indicated above <br />