My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 9:06:08 AM
Creation date
6/23/2020 6:58:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_2014-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax. (209) 468-3433 Web: www.sjgov.ora/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility <br />Name: <br />Chevron #208117 <br />Facility 755 S. Trac Blvd. Trac <br />Address: y , y <br />Inspection Mar 3, 2014 <br />Date: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safe Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (Mi) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 <br />1 10ther: <br />See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />ROUTINE ANNUAL INSPECTION AND MONITORING SYSTEM CERTIFICATION <br />Class I I violations: (109, 110, 111, 204, 311) <br />109, 110, & 111. Annual monitoring system certification, leak detector testing, and spill container <br />testing were last performed on February 27, 2013 and was completed on March 3, 2014, one month <br />past due. These tests are required once every 12 months. Take all necessary precautions to ensure <br />testing is performed in a timely manner. <br />204. The designated operator failed to check and note the correct test dates on the November 2013 <br />designated operator monthly inspection report. The test dates section of the inspection report was left <br />blank. During the monthly inspection, the designated operator shall check that all required testing and <br />maintenance for the UST system have been completed and document the dates they were done. <br />Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. REPEAT VIOLATION <br />311. The 91 line leak detector failed to detect a leak when tested. All line leak detectors shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, <br />and certified contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) and <br />obtain a permit within one business day from the EHD. If the failed leak detector can't be replaced <br />immediately, there is a possibility that the 91 UST system may be red tagged to prevent fuel inputs. <br />REPEAT VIOLATION <br />Complete and submit a copy of the Return to Compliance Certification to the EHD by April 3, 2014 along <br />with a statement documenting the corrective actions that have been or will be taken for each violation <br />and any supporting paperwork. <br />Provided: Return to Compliance Certification form <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />
The URL can be used to link to this page
Your browser does not support the video tag.