My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 9:06:08 AM
Creation date
6/23/2020 6:58:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_2014-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SMARTSENSOR ALARMS <br />ALL:COMMUNICATION ALARM <br />100.1 INCH VOL <br />94.2 INCH VOL <br />13820 <br />13005 <br />ALL:SENSOR FAULT ALARM <br />88.3 INCH VOL <br />12224 <br />ALL:FUEL WARNING <br />82.4 INCH VOL <br />11375 <br />ALL:FUEL ALARM <br />76.5 INCH VOL <br />10470 <br />ALL:WATER WARNING <br />70.6 INCH VOL <br />9515 <br />ALL:WATER ALARM <br />64.8 INCH VOL <br />8559 <br />ALL:HIGH LIQUID WARNING <br />58.9 INCH VOL <br />7580 <br />ALL:HIGH LIQUID ALARM <br />53.0 INCH VOL <br />6587 <br />DIAL TIME SETUP: <br />ALL:LOW LIQUID WARNING <br />47.1 INCH VOL <br />5600 <br />AUTO <br />ALL:LOW LIQUID ALARM <br />41.2 INCH VOL <br />4630 <br />ALL:INSTALL ALARM <br />35.3 INCH VOL <br />3740 <br />ALL:SENSOR FAULT WARN <br />29.4 INCH VOL <br />2880 <br />D B:Maintenance <br />ALL:VACUUM WARNING <br />23.5 INCH VOL <br />2079 <br />DIAL ON DATE <br />ALL:NO VACUUM ALARM <br />17.7 INCH VOL <br />1380 <br />SEP 6, 2013 <br />11.8 INCH VOL <br />770 <br />DIAL TIME : DISABLED <br />ISD SITE ALARMS <br />5.9 INCH VOL <br />295 <br />RECEIVER REPORTS: <br />ISD STAGE I WARN <br />ISD GROSS PRES WARN <br />ISD GROSS PRES FAIL <br />FLOAT SIZE: 4.0 <br />IN. <br />ISD DEGRD PRES WARN <br />ISD DEGRD PRES FAIL <br />WATER WARNING <br />1.0 <br />ISD VAPOR LEAK WARN <br />HIGH WATER LIMIT: <br />2.0 <br />ISD VAPOR LEAK FAIL <br />ISD VP PRES WARN <br />MAX OR LABEL VOL: <br />14976 <br />OVERFILL LIMIT <br />90% <br />ISD VP PRES FAIL <br />13478 <br />ISD VP STATUS WARN <br />HIGH PRODUCT <br />95% <br />ISD VP STATUS FAIL <br />14227 <br />MISSING RELAY SETUP <br />DELIVERY LIMIT <br />5% <br />MISSING HOSE SETUP <br />748 <br />RS -232 END OF MESSAGE <br />MISSING TANK SETUP <br />MISS VAPOR FLOW MTR <br />LOW PRODUCT <br />1000 <br />DISABLED <br />MISS VAPOR PRES SEN <br />LEAK ALARM LIMIT: <br />99 <br />DIAL ALARM SETUP <br />MISSING VP INPUT <br />SUDDEN LOSS LIMIT: <br />99 <br />AUTO <br />ISD SETUP WARN <br />TANK TILT <br />0.00 <br />ISD SETUP FAIL <br />PROBE OFFSET <br />0.00 <br />ISD SENSOR OUT WARN <br />D 8:Maintenance <br />ISD SENSOR OUT FAIL <br />PC -ISD FAILURE <br />SIPHON MANIFOLDED TANKS <br />IN -TANK ALARMS <br />TO: NONE <br />ALL:LEAK ALARM <br />ALL:HIGH WATER ALARM <br />ISD HOSE ALARMS <br />LINE MANIFOLDED TANKS <br />ALL:OVERFILL ALARM <br />ALL:GROSS COLLECT WARN <br />TO: NONE <br />ALL:LOW PRODUCT ALARM <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT WARN <br />ALL:SUDDEN LOSS ALARM <br />ALL:HIGH PRODUCT ALARM <br />ALL:DEGRD COLLECT FAIL <br />LEAK MIN PERIODIC: <br />0% <br />ALL:INVALID FUEL LEVEL <br />ALL:FLOW COLLECT WARN <br />ALL:FLOW COLLECT FAIL <br />0 <br />ALL:PROBE OUT <br />ALL:HIGH WATER WARNING <br />ALL:AIRFLOW MTR SETUP <br />LEAK MIN ANNUAL <br />0% <br />ALL:DELIVERY NEEDED <br />VAPOR FLW MTR ALMS <br />0 <br />ALL:MAX PRODUCT ALARM <br />ALL:CHK VAPOR FLOW MTR <br />ALL:GROSS TEST FAIL <br />PERIODIC TEST TYPE <br />ALL:PERIODIC TEST FAIL <br />PMC ALARMS <br />STANDARD <br />ALL:ANNUAL TEST FAIL <br />VP RUNTIME FAULT <br />ALL:NO CSLD IDLE TIME <br />ALL:GROSS FAIL LINE TNK <br />VP EMISSIONS WARN <br />ANNUAL TEST FAIL <br />VP EMISSIONS FAIL <br />ALARM DISABLED <br />LIQUID SENSOR ALMS <br />VP PRESSURE WARN <br />VP PRESSURE FAIL <br />PERIODIC TEST FAIL <br />ALL:FUEL ALARM <br />ALL:SENSOR OUT ALARM <br />VP DUTY CYCLE WARN <br />ALARM DISABLED <br />ALL:SHORT ALARM <br />VP DUTY CYCLE FAIL <br />PMC SETUP FAIL <br />GROSS TEST FAIL <br />ALL:WATER ALARM <br />ALL:WATER OUT ALARM <br />ALARM DISABLED <br />ALL:HIGH LIQUID ALARM <br />ANN TEST AVERAGING: <br />OFF <br />ALL:LOW LIQUID ALARM <br />PER TEST AVERAGING: <br />OFF <br />ALL:LIQUID WARNING <br />COMM SIDE DIM ALM <br />TANK TEST NOTIFY: <br />OFF <br />ALL:DISABLED DIM ALARM <br />ALL:COMMUNICATION ALARM <br />TNK TST SIPHON BREAKOFF <br />PRESSURE LINE LEAK <br />DELIVERY DELAY <br />PUMP THRESHOLD <br />5 MIN <br />10.00% <br />ALL:GROSS LINE FAIL <br />IN -TANK SETUP <br />ALL:ANNUAL LINE FAIL <br />- - - - - - - - - - - - <br />ALL:PLLD OPEN ALARM <br />T I:SUPREME <br />ALL:PLLD SHUTDOWN ALARM <br />PRODUCT CODE I <br />ALL:PERIODIC LINE FAIL <br />ALL:LOW PRESSURE ALARM <br />THERMAL COEFF :.000700 <br />ALL:UNKNOWN ALARM <br />TANK DIAMETER 117.75 <br />ALL:CONT HANDLE ALM <br />TANK PROFILE 20 PTS <br />FULL VOL 14976 <br />ALL:FUEL OUT <br />ALL:LN EQUIP FAULT ALM <br />111.9 INCH VOL 14724 <br />I 106.0 INCH VOL 14303 <br />
The URL can be used to link to this page
Your browser does not support the video tag.