Laserfiche WebLink
0 <br />SWRCB, January 2006 <br />Spill Bucket Testing Report Form <br />This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br />printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br />t_ FACTT.TTV INFORMATION <br />Facility Name: PACIFIC CAR WASH Date of Testing: 05-25-10 <br />Facility Address: 4405 PACIFIC AVE STOCKTON CALIFORNIA 95207 <br />Facility Contact: GREG / TAMMIE Phone: 209-478-5504 <br />Date Local Agency Was Notified of Testing A-30-10 <br />Name of Local Agency Inspector (i(present during testing): SAN JOAQUIN CO. GARRETT <br />Company Name: AFFORDA TEST 4162 d Street Galt, CA 95632 (209) 744-0112 Fax: (209) 744-0116 <br />Technician Conducting Test: ❑ Lyle D. Nimmo ❑ Zane A. Nimmo ❑ David A. Winkler ® Felix G. Ramirez <br />5249115 -UT 5263322 -UT 5263373 -UT 5273934 -UT <br />Credentials': ® ICC Service Tech. ® SWRCB Tank Tester <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other <br />Test Equipment Used: TAPE / H2O <br />Equipment Resolution: 1/16 <br />2 91 <br />3 <br />4 <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc.) <br />1 87 <br />Bucket Installation Type: <br />® Direct Bury <br />❑ Contained in Sump <br />® Direct Bury <br />❑ Contained in Sump <br />❑ Direct Bury <br />❑ Contained in <br />Sump <br />❑ Direct Bury <br />❑ Contained in <br />Sum <br />Bucket Diameter: <br />11 <br />11 <br />Bucket Depth: <br />14 <br />13 <br />Wait time between applying <br />vacuum/water and start of test: <br />- <br />Test Start Time (TI): <br />900 <br />900 <br />Initial Reading (Rj): <br />13 <br />12 <br />Test End Time (TF): <br />1000 <br />1000 <br />Final Reading (RF): <br />13 <br />12 <br />Test Duration (TF — TI): <br />1 HOUR <br />1 HOUR <br />Change in Reading (RF - RI): <br />0 <br />0 <br />Pass/Fail Threshold or <br />Criteria: <br />1/16 <br />1/16 <br />Test Result. Fess } 1[+` xl �,,tass 'El �`ar1 . ❑ Pass; [] Fail ; ❑Pass ❑Fail <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: Date:5-25-10 <br />' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />