My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4405
>
2300 - Underground Storage Tank Program
>
PR0508452
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:04:02 PM
Creation date
6/23/2020 6:58:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0508452
PE
2361
FACILITY_ID
FA0007787
FACILITY_NAME
PACIFIC CAR WASH/MARKETPLACE INC
STREET_NUMBER
4405
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11024013
CURRENT_STATUS
01
SITE_LOCATION
4405 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508452_4405 PACIFIC_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
267
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY 10 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s*gov.org/ehd/unitiii.html <br />CONTINUATION FORM <br />Page: 3 of 3 <br />OFFICIAL INSPECTION REPORT <br />Date: 05/26/11 <br />Facility Address: 4405 Pacific Ave, Stockton <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS 1, CLASS II, or MINOR -Notice to Comply) <br />Routine and Monitoring System Certification UST inspection <br />4. Financial responsibility documents have not been submitted to the Environmental Health Department <br />(EHD). Current financial responsibility documents are required to be submitted annually. Complete and <br />submit a copy of the financial responsibility by June 26, 2011. <br />5. The monitoring and response plans on site are not on the current forms. The monitoring and <br />response plans must be current and approved by the EHD. Complete and submit a copy of the <br />monitoring and response plans for approval by the EHD by June 26, 2011. An approved copy will be <br />returned for your records. <br />10 & 12. The 87 and 91 (split tank) annular sensor failed to activate an audible and visual alarm when <br />tested and, therefore, the tank is not monitored. The interstitial space shall be monitored with a <br />monitoring system connected to an audible and visual alarm system. Immediately contact a properly <br />licensed, trained, and certified contractor to replace the failed component with a functional component <br />(LG 113-x listed, if applicable) under permit and inspection of the EHD within one business day. <br />27. The dispenser sump liquid sensors and the 87 product turbine sump liquid sensor did not shut down <br />the 87 product turbine pump and the UST system does not meet the requirements for annual line <br />tightness testing exemption. Annual line tightness testing is required unless the UST system is <br />equipped with the following: <br />1. A continuous monitoring system that either activates an audible and visual alarm or stops the flow <br />of product at the dispenser when it detects a leak <br />2. A monitoring system that shuts down the pump or stops the flow of product at the dispenser when <br />it detects a leak <br />3. A monitoring system for piping other than that in UDC sumps (tank top sumps, transition vents, <br />etc.) is fail safe and shuts down pump when a leak is detected <br />Immediately schedule this test and provide 48 hours notification to the EHD or contact a properly <br />licensed, trained, and certified contractor to replace / repair the 87 turbine relay switch under permit and <br />inspection of the EHD. <br />Notes <br />1. Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br />each violation was corrected, including supporting documentation, by June 26, 2011. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE ($122). <br />THIS FACILITY IS SUBJECT TO REINSPE ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD InspeI <br />/ IIIXA �)� <br />R,* ITitle: <br />v <br />K I IF' �\ <br />I <br />EHD 'O 08/100 ' <br />23Rev �� \ CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.