IED PROGRAM CONSOLIDATED FORW <br />TANKS <br />UNDERGROUND STORAGE KS - TANK PAGE 2 <br />VI. PIPING CONSTRUCTION (Check all that apply) Page _ of <br />UNDERGROUND PIPING ABOVEGROUND PIPING <br />SYSTEM TYPE ® 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY 458 [11. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY 459 <br />CONSTRUc110N ❑ 1. SINGLE WALL ❑ 3. LINED TRENCH ❑ 99. OTHER 460 ❑ 1. SINGLE WALL ❑ 95. UNKNOWN 462 <br />MANUFACTURER ® 2. DOUBLE WALL ❑ 95. UNKNOWN ❑ 2. DOUBLE WALL ❑ 99. OTHER <br />MANUFACTURER Smith Fiberglass 461 MANUFACTURER 463 <br />❑ 1. BARE STEEL ® 6. FRP COMPATIBLE w/l00% METHANoI. ❑ 1. BARE STEEL ❑ 6. FRP COMPATIBLE wnoo%NEmA oL <br />❑ 2. STAINLESS STEEL [17. GALVANIZED STEEL ❑ Unknown ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br />❑ 3. PLASTIC COMPATIBLE W/ CONTENTS ❑ 99. Other ❑ 3. PLASTIC COMPATIBLE W/ CONTENTS ❑ 8. FLEXIBLE (HDPE) ❑ 99. OTHER <br />❑ 4. FIBERGLASS ❑ 8. FLEXIBLE (HDPE) ❑ 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br />❑ 5. STEEL W/COATING [19. CATHODIC PROTECTION 464 ❑ 5. STEEL W/COATING ❑ 95. UNKNOWN 465 <br />VII. PIPING LEAK DETECTION (Check all that apply) (A description of the monitoring program shall be submitted to the local <br />agency.) <br />UNDERGROUND PIPING ABOVEGROUND PIPING <br />SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br />PRESSURIZED PIPING (Check all that apply): PRESSURIZED PIPING (Check all that apply): <br />❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br />OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION + SHUT OFF FOR LEAK, SYSTEM FAILURE, AND SYSTEM DISCONNECTION + <br />AUDIBLE AND VISUAL ALARMS. AUDIBLE AND VISUAL ALARMS. <br />❑ 2. MONTHLY 0.2 GPH TEST ❑ 2. MONTHLY 0.2 GPH TEST <br />❑ 3. ANNUAL INTEGRITY TEST (O.1GPH) ❑ 3. ANNUAL INTEGRITY TEST (O.IGPH) <br />[14. DAILY VISUAL CHECK <br />CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS (Check all that apply) <br />❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM + TRIENNIAL PIPING <br />INTEGRITY TEST (0.1 GPH) El5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br />SAFE SUCTION SYSTEMS (NO VALUES IN BELOW GROUNDPIPING): ❑ 6. TRIENNIAL INTEGRITY TEST (0.1 GPH) <br />❑ 7. SELF MONITORING SAFE SUCTION SYSTEMS (NO VALVES IN BELOW GROUND PIPING): <br />GRAVITY FLOW ❑ 7. SELF MONITORING <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1 GPH) GRAVITY FLOW (Check all that apply): <br />❑ 8. DAILY VISUAL MONITORING <br />❑ 9. BIENNIAL INTEGRITY TEST (0.1 GPH) <br />SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br />PRESSURIZED PIPING (check all that apply):. PRESSURIZED PIPING (Check all that apply): <br />10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br />ALARMS AND (Check one) ALARMS AND (Check one) <br />❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br />® b. AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM ❑ b AUTO PUMP SHUT OFF FOR LEAKS, SYSTEM FAILURE AND SYSTEM <br />DISCONNECTION DISCONNECTION <br />❑c. NO AUTO PUMP SHUT OFF ❑c NO AUTO PUMP SHUT OFF <br />® 11. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITH FLOW SHUT <br />OFF OR RESTRICTION ®I I. AUTOMATIC LEAK DETECTOR <br />❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) ❑ 12. ANNUAL INTEGRITY TEST (0.1 GPH) <br />SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br />❑ 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR + AUDIBLE AND VISUAL ALARMS <br />EMERGENCY GENERATORS ONLY (Check all that apply) EMERGENCY GENERATORS ONLY (Check all that apply) <br />❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF • ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF a <br />AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br />❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW <br />SHUT OFF OR RESTRICTION ❑ 15. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) <br />❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) ❑ 16. ANNUAL INTEGRITY TEST (0.1 GPH) <br />❑ 17. DAILY VISUAL CHECK ❑ 17. DAILY VISUAL CHECK <br />VIIL DISPENSER CONTAINMENT <br />DISPENSER CONTAINMENT ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br />DATE INSTALLED 468 ❑ 2. CONTINUOUS DISPENSER PAN SENSOR + AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER / MONITORING <br />® 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑ 6. NONE a69 <br />DISPENSER + AUDIBLE AND VISUAL ALARMS <br />IX. OWNER/OPERATOR SIGNATI)RE <br />I certify that the information provided herein is true and accurate to the best of my knowledge. <br />IW REOF OWNIIDPERATOR DATE 470 <br />CD <br />NAME OF OWNER/OPRATOR (print) 471 TITLE OF OWNER/OPERATOR 472 <br />Dan Dixon Member <br />Permit Number (For local use only) 473 Permit Approved (For local use only) 474 Pernut E <br />xpiration Date (For local use only) 475 <br />UPCF (12/99 revised) 12 Formerly SWRCB Form B <br />