My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
322
>
2300 - Underground Storage Tank Program
>
PR0516472
>
COMPLIANCE INFO_2000-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 12:47:09 PM
Creation date
6/23/2020 6:58:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2009
RECORD_ID
PR0516472
PE
2361
FACILITY_ID
FA0012628
FACILITY_NAME
UNITED #5449
STREET_NUMBER
322
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14906111
CURRENT_STATUS
01
SITE_LOCATION
322 S CENTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516472_322 S CENTER_2000-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
364
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />5 WRCB, January 2002 Page 4of <br />6. PIPING SUMP TESTING <br />Test iMethod Developed By: 0 Sump Manufacturer U Industry Standard F] Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum Hydrostatic <br />0 Other (Specify) <br />Test Equipment Used: ` Equipment Resolution <br />Sump-# <br />S"M #.- <br />JJj�.. <br />Sump <br /># <br />Sump Diameter <br />Sump Depth. <br />Sump F <br />Height from Tank Top to Top of <br />Highest Piping Penetration: ` t< <br />r <br />Height from Tank Top to Locest / <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />v <br />Portion of Sump Tested" <br />Does turbine shut down when <br />sump sensor detects liquid (both ❑ Yes ❑ No ❑ NA <br />product and u"ater)?' <br />OYesPiq5o ❑ NA <br />[]Yes ,C No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Turbine shutdown response time <br />Is system programmed for fail-safe ❑ Yes ❑ Nd ❑ NA <br />shutdown `' <br />❑Yes ❑ No C NA <br />❑ Yes ❑ No 0 N <br />❑Yes LZ No ? NA <br />Was fain safe verified To be <br />operational?' ,,V" s ❑ No C NA <br />0 Yes ❑ No ❑ NA <br />❑ Yes E No ❑ NA <br />G Yes 0 N ❑ NA <br />Wait time betmveen applying <br />pressure/vacuum/water and starting _ <br />test: <br />Test Start Time: <br />J <br />Initial Reading (R4): s <br />Test End Time: <br />Final Reading (RF):, <br />b <br />g <br />Test Duration" , <br />r <br />Change in Reading (Rr-RI): <br />Pass/Fad Threshold or Criteria: <br />, <br />Test Result: Pass ❑ Fal <br />Pass ❑ Pain <br />❑ Pass ❑ Fail <br />11 Pass ❑ Fail <br />Was sensor removed for ? ..Yes L No ❑ NA <br />Yes ❑ No [INA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No [INA <br />Was sensor properly replaced and <br />, `g Yes u No ❑ NA <br />�-er�� functional � <br />KYeS ❑ No ENA <br />� Yes C ;'da ❑NA <br />IJ Y2S � Na O NA <br />er testing: �' <br />COmments — )include information on repairs made prior to testing, and recommended follow-up forfailed tests) f� <br />If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "Na" or "NA", the entire sump must be tested. (See SWRCB LG -160') <br />
The URL can be used to link to this page
Your browser does not support the video tag.