Laserfiche WebLink
ONITO NG SYSTEM CERTIFICATION <br /> F By All Jurisdictions Within the State of Califomia AN <br /> ' Authority Cited:Chapter 6.7,He and Safety Code;Chapter 16,Division 3 Title 23, CXWnia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: FLYING"J"0500079 City: LODI CA Zip:95242 <br /> Site Address: 15237 THORNTON RD Contact Phone No: 339-4066 <br /> Date of Testing/Service: 11/06/2008 <br /> Facility Contact Person: DONNA TOMPKINS <br /> Make/Model of Monitoring System:TLS-350 Work Order Number: 2261014 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: DIESEL-1 Tank ID: DIESEL-2 <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 303 MX Annular Space or Vault Sensor. Model: 303 <br /> X Piping Sump/Trench Sensor(s). Model: 322 Piping Sump/Trench Sensor(s). Model: 322 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: El Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: ElElectronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). D Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: UIESEL-3 Tank ID: 87-4 <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 303 Annular Space or Vault Sensor. Model: 303 <br /> X Piping Sump/Trench Sensor(s). Model: 322 X Piping Sump/Trench Sensor(s). Model: 322 <br /> Fill Sump Sensor(s), Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> ®Dispenser Containment Sensor(s) Model: 302 X Dispenser Containment Sensor(s) Model: 302 <br /> Shear Valve(s). Shear Valves) <br /> ElDispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> X]Dispenser Containment Sensor(s) Model:302 _Xj Dispenser Containment Sensor(s). Model:302 <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9/10 Dispenser ID: 11/12 <br /> Dispenser Containment Sensor(s) Model: 302 _IAI Dispenser Containment Sensor(s). Model:302 <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports, I have also attached <br /> a copy of the(Check all that apply): FX System set-up X❑Alarm history report <br /> Technician Name(print): BRIAN MCPHEELY Signature: <br /> Certification No.: B36745 License.No.: 743160(Class'A'General Enginering Contractor License) <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 11/06/2008 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />