My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_1988-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 4:09:45 PM
Creation date
6/23/2020 6:59:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2002
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_1988-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> Site Location: 1812 COLEY AVE Tracer Job No.: 30817U-0239 <br /> Tank Piping Tracer <br /> System: Volume: Product: Type: Material: Material: Tracer: Detected: <br /> DW/Steel DW/Steel <br /> Tank 794 500 gal Diesel UST/Piping UST/PipingSteel Clad Fiberglass A Pass <br /> Testing Events: System Survey Information: <br /> Installation: 06/27/2003 Pump System Style: Suction <br /> Inoculation: 06/27/2003, Inventory Monitoring Method: ATG <br /> Sampling: 07/29/2003 Tank Innerstitial Sensors? Yes <br /> Analysis: 08/07/2003 Tank Sump Sensors? Yes <br /> Dispenser Containment? No <br /> Installation Conditions: Dispenser Monitoring: N/A <br /> Backfill: Sand Vapor Recovery Style: N/A <br /> Ground Cover: Concrete Soil Permeability: >26.1 Darcys <br /> Asphalt <br /> Water/Fuel: Reading: Fill Riser/Spill Bucket Test: <br /> Groundwater: 75" See <br /> Test Duration: Comments <br /> Top of Tank: 34" Start Level: 0.00" <br /> Bottom of Tank: 86" End Level: 0.00" <br /> Product at Inoc: 41" Pass/Fail: Fail <br /> at Sampling: 38" Water was placed in the spill containment bucket for two hours— <br /> Fall=loss of wafer,Pass=no loss. Loss of water indicates faulty <br /> H2O at I noc.: 1" drain valve or spill bucket/riser connection. No inspection was <br /> at Sampling: 1" conducted to determine if loss impacted the backfill. <br /> Tank 794-Data Analysis: <br /> Probe: A iL <br /> 1 0.000 <br /> 2 0.000 <br /> 3 0.000 <br /> 4 0.000 <br /> 5 0.000 <br /> 6 0.000 <br /> 7 0.000 <br /> ATG1 0.000 <br /> F1 0.000 <br /> TS1 0.000 <br /> No Tracer A was detected in the backfill-No additional action is required. <br />