My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_1988-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 4:09:45 PM
Creation date
6/23/2020 6:59:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2002
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_1988-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
d <br /> �$®GRAM CONSOLIDATED F <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAG 1 <br /> y /2 OBJ (two pages per tank) <br /> Page_of <br /> TYPE OF ACTION ❑1 NEW SrrF PERMIT ❑ 4 AMENDED PERMIT , 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (specify reason-for local use only) (Specify reason-for local use only) 8 TANKREMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business, FACILITY ID: 1 <br /> 3 _ <br /> SBC#ESCLCAI l <br /> LOCATION WITHIN SITE(Optional) 431 <br /> I.TANK DESCRIPTION (A scaled plot pian with the location ofthe UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes 9 No 434 <br /> 1 0 Jaor If"Yes",complete one page for each compartment <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> Unknown 500 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> H.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ®1.MOTOR VEHICLE FUEL ❑la. REGULARUNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (Ifmarked complete Petroleum Type) (I 1b. PREMIUMUNLEADFD ®3. DIESEL 06. AVIATION FUEL <br /> ❑2.NON-FUELPETROLEUM ❑lc. MIDGiADEUNLEADED ❑4. GASOHOL ❑99.OTHER <br /> [13. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials lnvwtory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> (Indudes Used Oil) . <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK 1. SINGLE WALL 3. SINGLE WALL WITH 0 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank N 1. BARE STEEL El 3. FIBERGLASS/PLASTIC ❑5. CONCRETE 95.UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL 114. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/l00%METHANOL [199.OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank 1. BARE STEEL 0 3. FIBERGLASS/PLASTIC 5. CONCRETE 0 95. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL 1@4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPITBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑lo.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 1.RUBBER LINED 0 3.EPDXY LINING 0 5.GLASS LINING 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ❑6 UNLINED ❑99 OTHER <br /> (Check one itaan only) (For local use only) <br /> OTHER CORROSION ❑1 NL NUFACTL PLED CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 448 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4IIv1PRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(looal use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ®1 SPILL CONTAINMENT Unk ®1 ALARM Unk ❑3 FILL TUBE SHUT OFF VALVE <br /> 0 2 DROP TUBE Unk ❑2 BALL FLOAT ❑4 EXEMPT <br /> JR 3 STRIKER PLATE Ua <br /> IV.TANK LEAK DETECTION(A description ofthe monitoring program shall be submitted to the local agency-) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MIG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE 0 2 CONTINUOUS INTERSTITIAL MONiTORIPJG <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANKTESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DA LAST USED(YR/MO/DAY) 455 ESTIMATED OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> y Z t, L ` gallons 0 Yes 0 No <br />
The URL can be used to link to this page
Your browser does not support the video tag.