My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_1988-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 4:09:45 PM
Creation date
6/23/2020 6:59:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2002
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_1988-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B <br /> The housing is constructed of polyester;the sensing <br /> element is a combination of conductive elastomer and <br /> float-switch technologies.The sensors can be reused after <br /> an alarm condition is sensed, without degradation to the <br /> sensing materials. Remove and clean the sensor,then <br /> reinstall for the same reliable sensing as when it was new. <br /> .; The Discriminating Dispenser Pan and Containment <br /> Sump Sensors are easily installed using Veeder-Root's <br /> Universal Sensor Mounting Kit. <br /> The Dispenser Pan and Containment Sump Sensors are <br /> warranted to be free from material defects for a period of <br /> one year from the date of installation or 15 months from the <br /> date of invoice. <br /> 1110- Low cost solution for total information Detection Ca:~ <br /> management ► Sensor Alarm Conditions: <br /> ► Float switches determine presence of fluid, • Fuel at any height on the sensor even when <br /> F P,,. P P floating on other liquid, triggers a Fuel Alarm. <br /> .:. .: er a{alr: �L ivo t. .evt l l..7: `f...1 6. y�r_"e vr^f <br /> "trip''points. ®Liquid Warning is triggered when liquid reaches <br /> 1.0"high on both Dispenser Pan and Contain- <br /> 00- Conductive elastomer differentiates between ment Sump Sensors. <br /> hydrocarbons and other liquids, and alarms • High Liquid Alarm is triggered when liquid <br /> when hydrocarbon is detected at any point reaches 8.0"on Dispenser Pan Sensor or 10"on <br /> on the sensor, Containment Sump Sensors. <br /> ►Accurate, reliable and reusable even ► Sensor should be tested in liquid at least once a <br /> after exposure to heavy concentrations year or as required by local codes. <br /> of hydrocarbons. Operating Capabilities <br /> ► Long-life, durable construction. ► Operating Temperature Range:-0°C to+70°C. <br /> Veeder-Root's Discriminating Dispenser Pan and Contain- ► Storage Temperature Range:-40°C to+70°C. <br /> ment Sump Sensors quickly and accurately detect the ► Cable Length:6 feet. <br /> presence of hydrocarbons or fluids, and differentiate be- ► Dispenser Pan Sensor Dimensions: 11.53"high, <br /> tween the two, in their respective locations. <br /> 2.13"diameter. <br /> Alarm conditions—Fuel, Liquid Warning, High Liquid Alarm, ► Containment Sump Sensor Dimensions:22.03" <br /> Sensor Out—detected by either sensor are indicated by high, 2.13"diameter <br /> an audible alarm, a displayed message, and a printed mes- <br /> sage on the TLS-3508,TLS-350,TLS-300i, or TLS-300C. ► Withstand removal and replacement from sensing <br /> They are also recorded as part of the Alarm History Report. environment without sensor damage. <br />
The URL can be used to link to this page
Your browser does not support the video tag.