My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_1988-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 4:09:45 PM
Creation date
6/23/2020 6:59:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2002
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_1988-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Results of Third Party Standard Evaluation <br /> k <br /> ~ .> <br /> Point Sensor Liquid Contact Product Detectors <br /> This form documents the performance of the cable sensor liquid contact leak detection system described below. <br /> The evaluation was conducted by the equipment manufacturer or a consultant to the manufacturer according to the <br /> Third Party Procedures developed according to the U.S. EPA's "Standard Test Procedure for Evaluating Leak <br /> Detection Methods: Liquid-Phase Out-of-Tank Product Detectors"1 <br /> Tank owners using this leak detection system should keep this form on file to prove compliance with the federal <br /> regulations. Tank owners should check with state and local agencies to verify that this form satisfies their <br /> requirements. <br /> Method Description - <br /> Name 350Serie, Ug ST Monitorin y9ems-, Models ILS 350 (serial #Beta 013,) & TLS 35n <br /> Version with Interstitial Liquid Sensor for Steel Tanks (Q7443gQ-420) <br /> Vendor Veeder-ROot Environmental Products <br /> 125 Powder Forest Drive <br /> (street address) <br /> Simsbury. CT 06070-2003 BOW 873-3313 <br /> (city) (state) (zip) (phone) <br /> Detector output type: ,Z_Qualitative <br /> Detector operating principle: _Electrical Conductivity Capacitance Change <br /> Interface Probe Product Permeable —Product Soluble Thermal Conductivity <br /> Pressure Switch Magnetic Switch Other Moat Switch <br /> Detector sampling frequency: Intermittent -Continuous <br /> Evaluation Results <br /> The detector described above was tested for its ability to detect test liquids in contact with the <br /> point sensor. The following parameters were determined: <br /> - Detection Accuracy - The measure of sensor response to the presence of liquids. <br /> - Response Time -Amount of time the detector must be exposed to liquid before.it responds. <br /> e Recovery Time - Amount of time that passes before the detector returns to its baseline reading <br /> after the test liquid is removed. <br /> - Lower Detection Limit - The smallest liquid concentration that the detector can reliably detect. <br /> - Product Activation Height - The height of liquid to cause sensor activation. <br /> - Specificity - Indicates the level of response, of the detector, to several different liquids. <br /> 1 Camegle Mellon Research Institute.Test Procedures for Third Party Evaluation of Leatection Methods:Point <br /> Sensor Liguld Contact Leak Detection cty�_em�:Final Report-November 11, 1991. <br /> Liquid Contact Product Detector-Results Form Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.