My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_1988-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 4:09:45 PM
Creation date
6/23/2020 6:59:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2002
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_1988-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California Edition:lune 1999 <br /> Veeder-Root <br /> TLS-350 Series,TLS-300/3001 <br /> y, Discriminating Dispenser Pan Sensor(794380-322) and Discriminating Containment Sump <br /> - Sensor(794380-352) <br /> LIQUID-PHASE INTERSTITIAL DETECTOR <br /> Detector: <br /> Output type: qualitative <br /> Sampling frequency: continuous <br /> Operating principle: product permeable, reed switch/float <br /> Test Results: polymer strip float switches <br /> Discriminating Containment Sump unleaded wate <br /> Sensor gasoline diesel - 1owigl <br /> Accuracy(%) 100 100 _ 100 __ 100 <br /> Response time(min) ^-10 2-12 hrs <1 sec <1 sec <br /> Recovery time(min) 17.2 17.2 <1 sec <1 sec <br /> Lower detection limit-height(cm) N/D N/D 3.48 31.2 <br /> Lower detection limit-thickness(cm) 0.0127 0.0127 N/A N/A <br /> DistriminxtiWDispenser Pan uolymer striv float switches <br /> Sensor unleaded water <br /> gasoline diesel low high <br /> Accuracy(%) 100 100 100 100 <br /> Response time(min) —10 2-12 hrs <1 sec <1 sec <br /> Recovery time(min) 17.2 17.2 <1 sec <1 sec <br /> Lower detection limit-height(cm) N/D N/D 3.43 19.4 <br /> Lower detection limit-thickness(cm) 0.0127 0.0127 N/A N/A <br /> Specificity Results: <br /> Activated:commercial gasoline,synthetic gasoline,diesel fuel,jet-A fuel,n-hexane,toluene,xylene(s),water <br /> Not activated:polymer strip sensor did not respond to water <br /> Comments: <br /> EPA and many states require detection of 1/8 inch(0.32 cm)of product for groundwater monitoring. <br /> Test procedures were modified by evaluator using EPA's"Standard Test Procedure for Evaluation Leak <br /> Detection Methods:Liquid-Phase Out-of-tank Liquid Product Detectors". <br /> Veeder-Root Evaluator:Ken Wilcox Associates <br /> 125 Powder Forest Dr. Tel: (816)795-7997 <br /> Simsbury,CT 06070-2003 <br /> Tel:(860)651-2700 Dates of Evaluation: 01/02/95,06/23/97,04/20/98 <br /> 7 <br /> Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the <br /> method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. <br /> 321 <br />
The URL can be used to link to this page
Your browser does not support the video tag.