Laserfiche WebLink
r '4 <br /> {=a <br /> The housing is constructed of polyester;the sensing <br /> element is a combination of conductive elastomer and <br /> float-switch technologies.The sensors can be reused after <br /> an alarm condition is sensed,without degradation to the <br /> sensing materials. Remove and clean the sensor,then <br /> reinstall for the same reliable sensing as when it was new. <br /> The Discriminating Dispenser Pan and Containment <br /> Sump Sensors are easily installed using Veeder-Root's <br /> Universal Sensor Mounting Kit. <br /> The Dispenser Pan and Containment Sump Sensors are <br /> warranted to be free from material defects for a period of <br /> one year from the date of installation or 15 months from the <br /> date of invoice. <br /> ► Low cost solution for total information Detection Capabilities <br /> management <br /> ► Sensor Alarm Conditions: <br /> ► Float switches determine presence of fluid, •Fuel at any height on the sensor even when <br /> and trigger alarms at low level and high level floating on other liquid, triggers a Fuel Alarm. <br /> "trip"points. •Liquid Warning is triggered when liquid reaches <br /> 1.0"high on both Dispenser Pan and Contain- <br /> Do- Conductive elastomer differentiates between ment Sump Sensors. <br /> hydrocarbons and other liquids, and alarms •High Liquid Alarm is triggered when liquid <br /> when hydrocarbon is detected at any point reaches 8.0"on Dispenser Pan Sensor or 10"on <br /> on the sensor. Containment Sump Sensors. <br /> ►Accurate, reliable and reusable even ► Sensor should be tested in liquid at least once a <br /> after exposure to heavy concentrations year or as required by local codes. <br /> of hydrocarbons. Operating Capabilities <br /> ► Long-life, durable construction. ► Operating Temperature Range:-0°C to+70°C. <br /> Veeder-Root's Discriminating Dispenser Pan and Contain- ► Storage Temperature Range:-40°C to+70°C. <br /> ment Sump Sensors quickly and accurately detect the ► Cable Length:6 feet. <br /> presence of hydrocarbons or fluids,and differentiate be- ►Dispenser Pan Sensor Dimensions: 11.53"high, <br /> tween the two,in their respective locations. 2.13"diameter. <br /> Alarm conditions—Fuel, Liquid Warning, High Liquid Alarm, <br /> Sensor Out—detected by either sensor are indicated by ® Containment Sump Sensor Dimensions:22.03 <br /> an audible alarm,a displayed message,and a printed mes- <br /> sage on the TLS-350R,TLS-350,TLS-300i,or TLS-300C. ► Withstand removal and replacement from sensing <br /> They are also recorded as part of the Alarm History Report. environment without sensor damage. <br />