My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_1988-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 4:09:45 PM
Creation date
6/23/2020 6:59:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2002
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_1988-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br /> 'AAWC <br /> Environmental Management P.O.Box 5095 <br /> Pacific Region Room 3E000 <br /> San Ramon,CA 94583 <br /> UST & AST MONITOR CERTIFICATION FOR <br /> Testing Date: 08-01-00 <br /> Next Due Date: 08-01-01 <br /> Site Location: PACIFIC BELL . Tank ID(s): 794 <br /> 1812 COLEY AVENUE CLLC Code: ESCLCA11 <br /> ESCALON Geo Parcel: UG-010 <br /> County: SAN JOAQUIN Site Contact: BRIAN BOOKMAN <br /> Site Contact Phone#: 209-472-3138 <br /> Make&Model of Monitor System(s): VEEDER ROOT TLS-2501 <br /> Serial#of Monitor System(s): 16144 <br /> Tankll Tank 2 Tank 3 Tank 4 <br /> Tank ID# 794 <br /> Type of Tank: (Single Wall or Double Wall)UST or AST DW-UST <br /> Tank Material(Composit,Fiberglass,etc.) COMP <br /> Contents of Tank: DSL <br /> Capacity of Tank: 500 <br /> Type of Product Line: (Gravity, Suction,Pressure) SUCTION <br /> Type of Piping: (Single Wall or Double Wall) DW <br /> ALL SYSTEMS Tankll Tank 2 Tank 3 Tank 4 Sensor Type <br /> Float,Discrim,etc. <br /> Annular Space Sensor: YES PASS FLOAT <br /> Fill Sump Sensor: <br /> Piping Sump Sensor: YES PASS IFLOAT <br /> Piping Trench Sensor: <br /> Dispenser Containment Sensor: <br /> Other Types(Sensors): Compartmented Tank(s) <br /> Type of Overfill Protection(mechanical,electronic,ball float) ELECTRONIC <br /> Type of Spill Containment(Make&Model) 5 GALLON EBW <br /> FOR PRESSURE TYPE SYSTEMS ONLY <br /> Tank 1 Tank 2 Tank 3 Tank 4 <br /> Is Mechanical Line Leak Detector Present&Tested?: <br /> Does the Turbine Shut-Down if System Detects a Leak?: <br /> Does Positive Shut Down Occur if Monitor System is turned off?: <br /> ALL SYSTEMS <br /> In-Tank Gauge Present Probe Type and Type of Leak Detection(Ex. .2 gph). YES CAP.2 <br /> Does the Monitoring System have Audible&Visual Alarms? YES <br /> Is the Monitoring System installed to prevent unauthorized tampering?: YES <br /> Is the Monitoring Devices operable as per manufacture's specifications? YES <br /> Testing Company: TAIT ENVIRONMENTAL SYSTEMS <br /> Date: 08-01-00 Technician: BRANDON HAM <br /> (Pri Name) <br /> Certified Tester's ID#: 39-3435 <br /> (Signature) <br />
The URL can be used to link to this page
Your browser does not support the video tag.