My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1988-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_1988-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 4:09:45 PM
Creation date
6/23/2020 6:59:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1988-2002
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_1988-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
403
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D �I <br /> moo <br /> 7v,. <br /> a• PROGRAM CONSOLEDATED <br /> UNDERGROUNDKS <br /> STORAGE TANKS- PAGE 1 <br /> Zn- <br /> Page_of- <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT 0 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Speefyreason-forlocatuse oWy) (Specify reason-forlocaluseonty) ❑ STANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME.DBA-Doing Business As) 3 FACILITY ID: _ 1 <br /> SBC#ESCLCAI l <br /> - =-• <br /> LOCATION WITHIN SITE(optional) - 431 <br /> L TANK 7DESCRIPTION (A scaled plot plan with the location ofthe UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ® No 434 <br /> 1 Modem If"Yes,completeonepageforeachcompartment <br /> DATE INSTALLED(YEARNO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 12004 ),000 <br /> ADDITIONAL DESCRIPTION(For local use only) <br /> 43s <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE, 440 <br /> L MOTOR VEHICLE FUEL ❑la. REGULARUNLEADED ❑2. LEADED ❑5. TET FUEL <br /> (Ifrnarked complde Petoleum Type) ❑Ib. PREMIUM UNLEADED <br /> ®3. DIESEL ❑6. AVIATION FUEL <br /> [12. NON-FUEL PETROLEUM ❑to. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> - <br /> 0 3. CHEMICAL PRODUCT COMMON NAME(from Harmdow Materials lnventorypaga) 441 CAS#(from Hwwdoos Matteuaals Inventory page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> Oncludes Used Oil) <br /> ❑95.UNKNOWN <br /> IIL TANK CONSTRUCTION <br /> TYPE OF TANK 1. SINGLE WALL 3. SINGLE WALL WITH 0 5. SINGLE WALL WITH DnERNAL BLADDER SYSTEM 443 <br /> (Checkoneitern only) EXTERIOR MEMBRANE LIVER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT [199. OTHER_ <br /> TANKMATERSAL-pimarytank 1.BARE STEEL 3. FIBERGLASS/PLASTIC 5. CONCRETE 95.UNKNOWN 444 <br /> (Check oneAem only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FFIBERGLASS 0 S.FRP COMnIBLE W/lo0%METHANOL ❑99.OTHBR <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank I.BARE STEEL 3. FIBERGLASS/PLASTIC 5. CONCRETE 95.-UN KNOWN 445 <br /> (Checkmeitem ordy) ❑2. STAINLESS STEEL N 4. STEEL CLAD W/FB3ERGLASS 138. FRP COMPTB3LE W/100'/a METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 13I.RUBBEgLlNED 3.EPDXY LINING 5.GLASS LINING 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING, ❑2 ALKYD LINING ❑4 PHENOLIC LINING ❑6 UNLINED ❑99 OTHER <br /> (Check one ft=only) <br /> (For loaf use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 44s 448 <br /> PROTECTION IFAPPLICABLE PROTECTION [14 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE <br /> (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(locd use only) 451 OVERFILL PROTECTION EQUIPMENT-YEAR INSTALLED 452 <br /> - (Check all that apply) ®I SPILL CONTAINMENT 2004 ®] ALARM 2004 0 3 FILL TUBE SHUT OFF VALVE <br /> 2 DROP TUBE 2004 ❑2 BALL FLOAT ❑4 EXEMPT <br /> ®3 STRIKER PLATE 2004 <br /> IV.TANK LEAK DETECTION(Adse4)6onofthemorawmgprogremshallbesubm nedtothelowl agency.) <br /> IF SINGLE WALL,TANK(check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING (Check one item only) <br /> (MIG) ❑i VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE H 2 CONTINUOUS zNrERSTiT IAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL moNITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑STANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE IN-FORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED bVITII INERT MATERIAL? 457 <br /> gallons 0 Yes 0 No <br />
The URL can be used to link to this page
Your browser does not support the video tag.