Laserfiche WebLink
0 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />nderground Storage 'tank Program In�s�l+�#ion Report <br />3 . <br />�R <br />Facility Name: <br />Facility Address: <br />Date: <br />AT&T CALIFORNIA - UG010 <br />1812 COLEY AVE, ESCALON <br />January 30, 2018 <br />UST System Qbservattans <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />❑ V ❑ R c COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R ❑ COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />❑ V ❑ R ❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V ❑ R ❑ COS <br />331 <br />CCR 2630(d) <br />Secondarily contained piping not maintained to allow liquid to drain into sump <br />❑ V ❑ R ❑ COS <br />332 <br />CCR 2631(b), 2631(d) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />❑ V ❑ R ❑ COS <br />tingle-YYalled Nod P>resaIacER�p�ng. .•` _ <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed ❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) ❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) ❑ V ❑ R ❑ COS <br />6 _V1 19W <br />,...; terolations <br />2010 <br />See below <br />Unlisted General violation ❑ V ❑ R ❑ COS <br />S[i AE YF VIOLATIONSlip <br />" C ' C. 3S ►l, of MINOR - Notice to Comply) _ . <br />Item # <br />Remarks <br />319 <br />CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br />Spill container failed to hold five gallons during testing. The technician on site, John Cascio, mentioned that there <br />was a possible drain valve issue and that it needed to be repaired. <br />All LISTS shall be equipped with a spill container that has a minimum capacity of five gallons and a drain valve that <br />allows drainage of the collected spill into the primary container or provide a means to keep the container empty. <br />Immediately contact a properly licensed, trained, and certified contractor to repair the spill container, under permit if <br />necessary. An inspection by EHD will be needed for the retest of the spill container and all EHD staff time <br />associated will be billed at the current rate of 152 dollars an hour. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by March 1, 2018. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />EHD 23-01 Rev. 09/22/16 <br />Page 3 of 4 <br />FA0003946 PR0231881 SCO01 01/30/2018 <br />Underground Storage Tank Program OIR <br />