Laserfiche WebLink
UG010 9 <br /> 0 <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(one form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections I,II,III,IV,and IX below) 430 <br /> ❑ 1.NEW PERMIT ❑ 3.RENEWAL PERMIT ® 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430a I DATE EXISTING UST DISCOVERED: 430b <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) _ - 1 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 <br /> Pacific Bell Telephone Company dba AT&T California UG010 <br /> BUSINESS SITE ADDRESS 103 1 CITY 104 <br /> 1812 Coley Avenue Escalon <br /> II.TANK DESCRIPTION <br /> TANK ID# 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> UG01 00001 MODERN WLD ®1.A STAND-ALONE TANK <br /> �. ❑2.ONE IN A COMPARTMENTED UNIT. <br /> Complete one page for each compartment in the unit. <br /> D TE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> 4/1/04 1000 1 <br /> III.TANK USE AND CONTENTS <br /> TANK USE ❑ la.MOTOR VEHICLE FUELING ❑ Ib.MARINA FUELING ❑ lc.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ® 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 439a <br /> CONTENTS PETROLEUM: ❑ 1 a.REGULAR UNLEADED ❑ Ic.MIDGRADE UNLEADED ❑ lb.PREMIUM UNLEADED 440 <br /> ® 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 440a <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> [311.OTHER NON-PETROLEUM(Specify): <br /> 4406 <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ® 1.STEEL ❑ 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 444a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ®3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify): 445a <br /> OVERFILL PREVENTION ® 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT ® 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑1.SINGLE-WALLED ®2.DOUBLE-WALLED [199.OTHER 460 <br /> SYSTEM TYPE ❑ 1.PRESSURE ❑ 2.GRAVITY 99 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR§2636(a)(3)] 458 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ® 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ® 8.FLEXIBLE ❑ 10.RIGID PLASTIC 4646 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 4644 <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464e <br /> 464e1 <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464f <br /> 464fl <br /> VR PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify) 464g <br /> 464 1 <br /> VR SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify) 464h <br /> 464h1 <br /> VENT PIPING TRANSITION SUMP TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90. ONE 464i <br /> RISER PRIMARY CONTAINMENT ® 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4641 <br /> 464'I <br /> RISER SECONDARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464k <br /> 464k1 <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET ® 3.STRIKER PLATE/BOTTOM PROTECTOR ® 4.CONTAINMENT SUMP 451 a-c <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ® 3.NO DISPENSERS ❑ 90.6NOA 469a <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469b-c <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ® 6.ISOLATION 448' <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system iompatible with the hazardous substance stored and that the information provided Uiih is true,accurate, <br /> and in full compliance with lVal r uir s. <br /> 470. <br /> APPLICANT SIGNATURE DATE <br /> 8/16/2012 <br /> APPLICANT NAME(print) 471' APPLICANT TITLE 472. <br /> Steven J Hall Manager EH&S <br /> UPCF UST-B <br /> Rev.(12/2007) <br />