My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2024 4:47:24 PM
Creation date
6/23/2020 6:59:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2002-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
404
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEW UST INSTALLATION INSPECTION RECORD <br /> FACILITY NAME: ADDRESS: <br /> Q <br /> PR# *U TANK# 05jS4l' UL# TANK MODEUMATERIAL: <br /> COMPARTMENTALIZED TANK? (If yes, complete one form for each tank) XYES ❑ NO <br /> TANK CAPACITY: PRODUCT: <br /> DATE A INITIALS <br /> P <br /> P <br /> R ALL TANKS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH MANUFACTURER WRITTEN <br /> SPECIFICATIONS <br /> E <br /> D <br /> 1. UST PLANS SUBMITTED AND FEES PAID (H&S CODE SECTION 25287 <br /> 1( 2. UST INSTALLATION PLANS APROVED <br /> INITIAL INSPECTIONS <br /> J 3. INSPECTION AND TEST OF SECONDARY C MENT: HOLIDAY TEST: VACUUM: <br /> SOAP: PSI: HRS/MIN: 1DRIWALIQUID ANNULAR): OTHER: <br /> 4. PRIMARY TANK TEST: <br /> 5. TANK APPROPRIATELY PLACED WITH APPROVED BACKFILL API/PEI <br /> PIPING INSPECTIONS <br /> 6. PRIMARY PIPING TEST MINIMUM 40 PSI/30 MIN CCR 2636 e <br /> 7. SECONDARY PIPING CONTAINMENT TEST: PSI: HRS/MIN: OTHER: FCCR 2636 e <br /> 8. LAKE TEST ON ALL SUMPS 24 HR MINIMUM HRS: FCCR 2635 a 4 <br /> 9. UNUSED TANK OPENINGS SEALED AND CORROSION PROTECTED PEI <br /> 10. OVERSPILL PERFORMANCE TEST CCR 2635 b 1 C <br /> 11.ALL PIPING AND FITTINGS CORROSION PROTECTED CCR 2636(b)] <br /> 12. PIPING SLOPES TO COLLECTION SUMP FCCR 2636 c 1 <br /> FINAL INSPECTION <br /> 13. PERFORMANCE TEST FOR"ALL"MONITORING PROBES CCR 2632 c 2 <br /> 14. PERFORMANCE TEST OF CONTINUOUS MONITORING SYSTEM fCCR 2632 c 2 <br /> 15. PERFORMANCE TEST OF LINE LEAK DETECTION ICCR 2643 c 1 <br /> 16. PERFORMANCE TEST OF AUTOMATIC PUMP SYSTEM SHUT OFF CCR 2636 <br /> 17. BALL FLOAT VALVES INSTALLED <br /> 18. OVERFILL PROTECTION INSTALLED AND APPROVED FCCR 2635 b 2 <br /> 19. TANK ACCESS PORTS BROUGHT TO GRADE LOCKED AND WATERTIGHT API <br /> 20. TANK INTEGRITY TEST PERFORMED HARD COPY SUBMITTED CCR 2635 a 5 <br /> 21. MONITORING PLAN RESPONSE PLAN AND LOG BOOK ON SITE CCR 2632 d <br /> 22."C"FORM COMPLETED AND SUBMITTED FCCR 2635' d <br /> 23. MONITORING METHOD FOR ALL TANKS AND PIPING APPROVED FCCR 2630-2636 <br /> 24. ALL CONDITIONS MET: FACILITY PERMIT ISSUED (H&S CODE 25284 <br /> COMMENTS <br /> EH23 006 3/18/02 <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.