My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2024 4:47:24 PM
Creation date
6/23/2020 6:59:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2002-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
404
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />= OPW 61T FILL DROP TUBES <br />The OPW 61T Drop Tube is installed in the fill riser pipe to an underground storage <br />tank. It is designed to transfer product from the fill connection point (between the <br />delivery drop elbow and tight -fill adaptor) to within 6" (or per local requirements) of the <br />bottom of the tank. This allows for submerged filling of the tank, resulting in a more <br />efficient delivery flow rate while reducing the build-up of vapors or foam in the tank. <br />Features: <br />♦ .052" Thick Drop Tube Walls - <br />Deter denting and damage to the <br />tube upon installation or removal for <br />long service life. <br />♦ Various Lengths and Diameters - <br />Accommodate a variety of tank <br />diameters and fill riser pipe sizes. <br />Ordering Specifications <br />Product No, <br />in. mm. <br />lbs. <br />kg. <br />Drop Tube <br />Length list <br />ft. M. Price <br />61T-7244 <br />3" "76 ' <br />3.14 <br />1.43 <br />10 3.05,_ $63.25 <br />61T-3015 <br />3" - i6` ' <br />4.5 <br />2.04' <br />15 437 $195.00 <br />61T-7266 <br />4" 1Q2;' <br />5.12 <br />233' <br />10 $A', $64.20 <br />61T-7268 <br />4" `102"; <br />6.18 <br />7,9,^^ <br />12 3:ir&' $69.75 <br />61T-7366 <br />4" 102' <br />7.65 <br />1348. <br />15 4.37' $103.70 <br />61T7468 <br />4" 102 <br />138. <br />17 5.19' $119.90 <br />61T-1012' <br />4" 102 <br />10.76 <br />4.88 <br />12 3.66 $137.40 <br />'Grooved tube <br />Replacement <br />are available. <br />gaskets for the 61T-4" and the 61 SO Series <br />Order the OPW 61TG (4000). <br />DPW 61TC COAXIAL FILL DROP TUBES <br />The OPW 61TC Coaxial Drop Tube is designed to replace an OPW 61T Conventional <br />Drop Tube when Stage I Vapor Recovery is required and a vapor recovery riser pipe <br />is not available on the tank or would require excavation to the top of the tank. The <br />61TC is used in conjunction with OPW 633TC Coaxial Vapor Recovery Adaptors to <br />return vapors to the tank truck, through one riser pipe, during a fuel delivery to an <br />underground storage tank. The upper section of the 61TC is tapered to allow vapors <br />to return to the tank truck through the interstitial space between the riser pipe and out- <br />side wall of the drop tube. Simultaneously, product is delivered to the tank through <br />the center of the 61TC. <br />DPW 61TCP POPPETED COAXIAL FILL DROP TUBES <br />The OPW 61TCP Poppeted Coaxial Fill Drop Tube is similar to the 61TC, but is <br />spring-loaded. When used in conjunction with the OPW 633TCP, the 61TCP acts as a <br />poppet to close off the vapor return side of the coaxial fill tube. (Adaptor not included) <br />Features: <br />♦ .052" Thick Drop Tube Walls - <br />Deter denting and damage to the <br />tube upon installation or removal for <br />long service life. <br />♦ Various Lengths and Diameters - <br />Accommodate a variety of tank <br />diameters and fill riser pipe sizes. <br />♦ Fully Welded Retaining Brackets - <br />Ensure a secure installation in the <br />riser pipe. <br />♦ Three Centering Springs - Enable <br />even flow of vapors back to the <br />tank truck. <br />Ordering <br />Specifications <br />Product No. <br />Diameter Length <br />Weight <br />list <br />in. <br />mm, ft m, <br />lbs. kg. <br />Price <br />61TC•7168 <br />3 <br />7 13 818 <br />6.75 3.07 <br />$148.00 <br />61TC-7270 <br />4 <br />101 13 `0N; <br />8.64 3.93' <br />$141.45 <br />61TC-7272 <br />4" <br />142 16 <br />13.82x6.281 <br />$203.85 <br />61TCP-3800 <br />4" <br />142' 13' <br />8.96 14.87: <br />S250.00 <br />OPW 61T <br />Lwkwm"Wwwnuc <br />0MEM <br />1SC-2100 Spill <br />Container <br />034TT <br />633TC, or . <br />633TCP <br />`x 61TC, or <br />61 T <br />.. CP <br />4" Riser Pipe <br />Underground <br />Tank <br />North America Toll Free - TELEPHONE: (800) 422-2525 • Fax: (800) 421-3297 • Email: domesticsales@opw-fc.com <br />O P VV`* International -TELEPHONE: (513) 870.3315 or (513) 870.3261 • Fax: (513) 870-3157 • Email: intlsales@opw-fc.com <br />www.opw-fc.com <br />@ Copyright 2003, OPW Fueling Components ♦ P.O. Box 405003 ♦ Cincinnati, OH 45240-5003 • Printed in USA • 3103 <br />